9. Error and information messages
HEAt
This message appears if you try to switch on the lamp within 5 minutes after having switched it off (the
lamp is too hot). The message will appear on the display if the lamp doesn't ignite within 28 seconds. The fixture
will store this information and automatically ignite the lamp when the 5 minutes period has expired.
LAEr
The ignition of the lamp is seven times unsuccessful (the HEAt message appeared six times before), and
the display shows
"
LAEr
"
, meaning that the lamp could be damaged or even missed, the fixture is overheating
(this can occur if the ambient temperature is 45° C or more) or there could be a failure on the ignitor or ballast.
Please place or replace the lamp, check the ambient temperature or contact your dealer if the situation was not
caused by the lamp.
FAn
The message informs you that the fixture was overheating and switched off. This message will appear on the
display if the fan speed operating "LOOF" was selected.
MbEr
This messsage informs you that the main PCB does not communicate correctly with the Control Board.
CoEr
(color-wheel error)
The messsage will appear after the reset of the fixture if the magnetic-indexing circuit malfunctions (sensor
failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The color-
wheel is not located in the default position after the reset.
rGEr
(rotating gobo-wheel error)
The message will appear after the reset of the fixture if the magnetic-indexing circuit malfunctions (sensor
failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The rotating
gobo-wheel is not located in the default position after the reset.
iGEr
(rotating gobo indexing error)
The message will appear after the reset of the fixture and if the magnetic-indexing circuit malfunctions
(sensor failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The
rotating gobo is not located in the default position after the reset.
PrEr
(prism error)
This message will appear after the reset of the fixture if the magnetic-indexing circuit malfunctions (sensor
failed or magnet missing) or the stepping-motor is defective (or its driver circuit on the main PCB). The prism-
wheel is not located in the default position after the reset.
FtEr
This error message informs you that the fixture was overheating (occured if the ambient temperature is
45° C or more) and that the relay switched off the lamp. This message will appear on the display until the
temperature will be on a suitable level, then the display will show the
massage
"HEAt"
meaning the lamp is too
hot (explanation see above).
SnEr
This message appears if the lamp lighting sensor is failed.
PoEr
This message will appear if the fixture was shortly disconnect from the main.
PAEr
(Pan-yoke movement error)
This message will appear after the reset of the fixture if the yokes magnetic-indexing circuits malfunction
(sensors failed or magnet missing) or the stepping motor is defective. (Or its driving IC on the main PCB). The
yoke is not located in the default position after the reset.
tiEr
(TILT-head movement error)
This message will appear after the reset of the fixture if the heads magnetic-indexing circuit malfunctions
(sensor failed or magnet missing) or the stepping motor is defective. (Or its driving IC on the main PCB). The
head is not located in the default position after the reset.