background image

14

6. Addressing

The control board on the front panel of the COLOR SPOT 250 allows you to assign the DMX fixture address,

which is defined as the first channel from which the COLOR SPOT 250 will respond to the controller.

If you set, for example, the address to channel 5, the COLOR SPOT 250 will use the channel 5 to 20 for control.

Please, be sure that you don’t have any overlapping channels in order to control each COLOR SPOT 250

correctly and independently from any other fixture on the DMX data link.

If two, three or more COLOR SPOT 250 are addressed similarly, they will work similarly.

For address setting follow this procedure:

1)

 Switch On the COLOR SPOT 250 and wait until the fixture reset has finished (

"rSt"

 is flashing at the display).

2)

 Press the

 [Mode]

 key in order to access the main menu. Browse through the menu  by pressing the 

[Up]

and

 [Down]

 keys until the display shows 

"A001"

. Confirm by  pressing 

[Enter]

 key and the letter 

"A"

 will  flash.

3)

 Use the

 [Up] 

and 

[Down] 

keys to select the desired address.

4)

 Confirm by pressing 

[Enter]

 or 

[Mode]

 to cancel.

Controlling:

After having addressed all COLOR SPOT 250 , you may now start operating these via your lighting controller.

Note:

After switching on, the COLOR SPOT 250 will automatically detect whether DMX 512 data is received or

not.

If there is no data received at the DMX-input, the display will start to  flash 

"A001"

 with actually set address.

This situation can occur if:

- the 3 PIN XLR plug (cable with DMX signal from controller) is not connected with the input of the COLOR

SPOT 250

- the controller is switched off or defective, if the cable or connector is defective or the signal wires are

swap in the input connector.

Note:

It’s necessary to insert the XLR termination plug (with 120 Ohm) in the last lighting in the link in order to

ensure proper transmission on the DMX data link.

7. Remotely controllable functions

7.1 Lamp

The COLOR SPOT 250 is run with a MSD 250W/200W lamp.

A relay inside of the COLOR SPOT 250 allows you to switch On and Off the lamp  via itself control board on the

front panel or via your controller without affecting the rest of the lighting.

7.2 Switching On and Off the lamp by the control board

1.

 Switch On the COLOR SPOT 250 and wait until the fixture reset has finished.

2.

 Press the 

[Mode]

 key in order to access the main menu. Browse through the menu by pressing the

 [Up]

 and

[Down]

 keys until the display shows 

"LAMP"

. Confirm by  pressing

 [Enter]

 key.

3.

 Use the 

[Up] 

and

 [Down]

 keys to select 

"On"

 for switch On the lamp and 

"Off"

 for  switch Off the lamp and

press

 [Enter]

 to confirm or 

[Mode] 

to cancel.

Note:

It is also important to note, that the discharge lamp is cold restrike types, that means, that they have to be

cold before re-striking. For this reason, you have to wait 5 minutes (max. speed of fan must be adjusted) after

having switched Off the lamp before you can switch it back On again. If you try to switch On the lamp within 5

minutes after having switched it Off, the COLOR SPOT 250 will store this information and automatically ignite the

lamp when the 5 minutes period has expired. The message 

"HEAt"

 will appear on the control board display at

the back side of the COLOR SPOT 250.  If the ignition of the lamp is seven times unsuccessful, on the display will

appear 

"LA.Er"

, meaning that the lamp could be damaged or even missed, or there could be a failure on the ignitor or

ballast.

7.3 Colour wheel

The COLOR SPOT 250 features a colour-wheel with 12 color positions - 11 of these with dichroic colors and the

last one open. The wheel can be positioned between two adjacent colors in any position. It is also possible to

rotate the color-wheel continuously at different speeds - the so-called "Rainbow effect“ is created.

Summary of Contents for Design Spot 250

Page 1: ...1 Version 1 0 COLOR SPOT 250...

Page 2: ...2...

Page 3: ...nnection connection between fixtures 11 5 DMX PROTOCOL 12 6 Addressing 14 7 Remotely controllable functions 14 7 1 Lamp 14 7 2 Switching On and Off the lamp by the control board 14 7 3Colour wheel 14...

Page 4: ...tion Make sure that the available voltage is not higher than stated on the rear panel Always plug in the power plug least Make sure that the power switch is set to OFF position before you connect the...

Page 5: ...rect holes only Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened The lamp must never be ignited if the objective lens or any housing...

Page 6: ...Yoke 3 Base 4 Carrying handles Rear panel 5 Power switch 6 DMX output 7 DMX input 8 Powercord 9 Fuseholder Front panel 10 Mode button 11 Enter button 12 Up button 13 Down button 14 Display 3 Descript...

Page 7: ...caused by non observance are not subject to warranty Please follow the lamp manufacturer s notes Do not touch the glass bulb bare hand during the installation Make sure that the lamp is installed tig...

Page 8: ...ving the lamp closer to the reflector Do so by turning srew A until the light is evenly distributed If the light on the edge seems to be brighter as in the center the lamp is too close at the reflecto...

Page 9: ...f the head by loosening the 4 Phillips screws on the front and rear sides of the top cover If you wish to use other forms and patterns as the standard gobos or if gobos are to be exchanged please foll...

Page 10: ...edproperly Ensure that the structure truss to whichyou are attaching the fixtures is secure The COLOR SPOT 250 can be placed directly on the stage floor or rigged in any orientation on a truss without...

Page 11: ...ion DMX output DMX input XLR mounting socket XLR mounting plug If you are using the standard DMX controllers you can connect the DMX output of the controller directly with the DMX input of the first f...

Page 12: ...140 229 No function step 230 239 Lamp off after 3 sec step 240 255 No function step 7 5 Colours 0 Open white proportional 10 Turquoise proportional 21 Red proportional 32 Cyan proportional 42 Green pr...

Page 13: ...to fast proportional 12 10 Rotating gobo index rotating gobo rotation 0 127 Gobo indexing proportional 128 190 Forwards gobo rotation from fast to slow proportional 191 192 No rotation step 193 255 B...

Page 14: ...ast lighting in the link in order to ensure proper transmission on the DMX data link 7 Remotely controllable functions 7 1 Lamp The COLOR SPOT 250 is run with a MSD 250W 200W lamp A relay inside of th...

Page 15: ...tomatically raises its speed in order to control inside temperature of the lighting if the temperature inside increases about certain level the low fan speed reduces the cooling of the lighting This c...

Page 16: ...select On if you wish the 16 bit high resolution or Off if you wish only 8 bit resolution and press Enter to confirm or Mode to cancel and return to the main menu Note If you adjust the 16 bit resolu...

Page 17: ...projections on the wall ceiling or ground without any head movement the Mod2 uses all COLOR SPOT 250 functions and therefore is good for a complete introduction of the fixture Reset function Press En...

Page 18: ...ng On the fixture and press Enter to confirm or Mode to cancel and return to the menu DMX values Readout DMX values of each channel received by the fixture Use the Up and Down keys to select desired c...

Page 19: ...operating Browse through this menu by the pressing Up and Down keys the display shows step by step these messages HIGH reG LoOF LoHI Press Enter if you wish to select one of them or Mode to cancel and...

Page 20: ...he fixture to the required desired position 0 255 before the function calibration Then when the positioning is finished use the last FCAL function Fixture calibration 1 Calibration via the control boa...

Page 21: ...mentioned below DMX Calibration protocol DMX chanel Function 1 Colour Calibration0 255 2 No function 3 Effect Calibration0 255 4 Rotating gobo Calibration0 255 5 Gobo rotating Calibration0 255 6 No f...

Page 22: ...e main PCB The rotating gobo wheel is not located in the default position after the reset iGEr rotating gobo indexing error The message will appear after the reset of the fixture and if the magnetic i...

Page 23: ...8 230 V AC 50 60Hz Fuse T 6 3 A 115V Fuse T 4 0 A 208V Power consumption 500 VA Compatible lamps MSD HSD 230 V 250W GY 9 5 or MSD HSD 230V 200W GY 9 5 Optical system High luminous efficiency parabolic...

Page 24: ...tating gobos rotating prism combinations Focus Remotely controllable motorized focus from near to far Motors 10 high quality stepping motors controlled by microprocessors Electronics Addressing specia...

Page 25: ...2 65 s Maximum TILT movement 280 in 1 68 s Remotely controllable speed of Pan Tilt movement for easy programming Rigging Stands directly on the floor Mounts horizontally or vertically with 2 clamps 2...

Page 26: ...el and the internal lenses should be cleaned monthly To ensure a proper function of the gobo wheel we recommend lubrication in six month intervals The quantity of oil must not be excessive in order to...

Reviews: