7
4. Installation
4.1Fitting the lamp
DANGER !
Install the lamps with the device switched off only.
Unplug from mains before !
To insert the lamp MSD 230 V/250 W or MSD 230 V/200 W open the top cover of the head (see the drawings
to identify which cover is top) by loosening the 4 Phillips screws on the front and rear sides of the top
cover.Then open the small lamp cover by loosening 3 fastening screws (see the drawing).If changing the
lamp, remove the old lamp from the socket. Insert the lamp to the socket.Do not install a lamp with a higher
wattage! A lamp like this generates temperatures the device is not designed for.Damages caused by non-
observance are not subject to warranty. Please follow the lamp manufacturers notes!Do not touch the glass-
bulb bare hand during the installation! Make sure that the lamp is installed tightly into the lampholder system.
Adjust the optimal distance 1-1.5 mm from the lens by turning
the screw
"A"
(see the drawings
"Lamp adjustment"
below).
Then close the small lamp cover by tighten 3 fastening
screws again.
Reclose the top cover of the head and tighten the 4 Phillips
screws
Before striking the lamp, reset the
"LAti"
counter in the main
menu of the Control Board, by pressing the
"Up"
and
"Down"
buttons in one time and then confirming with the
Enter
-button.
Do not operate this fixture with opened housing-cover!
2 Phillips screws
2 Phillips screws
Top cover
Bottom cover
Bottom cover
Lamp
Lamp cover
3 fastening
screws