Elation ART SSC Setup Manual Download Page 7

Supported Protocols

The Art SSC is fitted with several communication ports and supports various protocols. This 
chapter describes these protocols.

DMX-512

Connect your lighting fixtures either to the DMX OUT A port or DMX OUT B. Use a 5-pin XLR cable 
to connect the Art SSC's DMX OUT port to the first fixture, from then on daisy-chain to all other 
fixtures.

3 Pin Adapter

If your cabling or fixtures are using a 3-pin XLR connector then you can 
obtain - or create yourself - a 5-to-3-pin adapter.

For both 5-pin and 3-pin connectors the pin-out is:

1 = GND

2 = Data-

3 = Data+

(on the 5-pin XLR pin 4 & 5 are not connected)

Cable

Use a shielded twisted pair cable for DMX cabling. The cable should be terminated with an 120 
Ohm resistor.

Overcoming DMX-512 Limitations

DMX-512 is a very successful protocol with, however, a few 
limitations. The maximum number of attached devices is limited 
to 32 and they all have to be connected in bus-topology having 
one cable running via each device. Furthermore, a DMX cable 
should not be longer than 300 meters.

The DMX Branch/4 from Elation Professional helps tackle those 
inconvenient limitations of DMX-512. The Splitter takes a DMX 
signal and sends it out again on its 4 DMX output ports allowing a star-topology for efficient cable 
usage. Each output port is capable of driving 32 more devices. The Splitter can also function as a 
signal booster as each port supports another 300 meter long connection.

RDM

RDM is a recent addition to the DMX-512 protocol. The DMX protocol was uni-directional. RDM 
makes it bi-directional and allows for the controller to receive status information from the fixtures 
and set properties like the fixture's starting address.

Both of the DMX outputs are RDM capable (the DMX input is not) and the RDM master 
functionality for collecting all the information and setting all the parameters will be implemented via 
an external software program (not available yet).

Art-Net

The Art-Net protocol primarily transfers DMX-512 data over Ethernet. The high bandwidth of a 

6

Summary of Contents for ART SSC

Page 1: ...MANUAL ART SSC SOLID STATE CONTROL...

Page 2: ...elp 2 Setting up 3 Mounting 3 Power 3 Network 4 Artman Software Tool 5 Supported Protocols 6 DMX 512 6 RDM 6 Art Net 6 SMPTE 7 MIDI 7 OSC 8 UDP 8 GPI 8 eTouch 9 Web based User Interface 10 Home 10 Lig...

Page 3: ...s this web interface during set up A browser or computer is not required for standalone use after the set up Features 2 independent optically isolated DMX 512 outputs optically isolated DMX 512 input...

Page 4: ...5 from Bopla Product no 22035000 This adapter is amongst others available from Farnell Newark order code 4189991 Conrad order code 539775 89 Distrelec order code 300060 19 Rack There will become avail...

Page 5: ...y default IP address is 192 168 1 10 with the sub net mask set to 255 255 255 0 Make sure your computer is in a valid address range e g set your computer to IP 192 168 1 9 with a sub net mask of 255 2...

Page 6: ...x is available via our website free of charge Artman allows you to change IP address and subnet set the Art SSC s date and time your computer s date and time will be used perform firmware updates do a...

Page 7: ...cted in bus topology having one cable running via each device Furthermore a DMX cable should not be longer than 300 meters The DMX Branch 4 from Elation Professional helps tackle those inconvenient li...

Page 8: ...which can be used to synchronize audio video lighting and other effects SMPTE information can be transferred through various media like audio channels video signals MIDI etc The Art SSC supports LTC...

Page 9: ...the Art SSC as a converter between OSC and MIDI UDP UDP User Datagram Protocol is a simple protocol for sending message across the network It is supported by various media devices like video projector...

Page 10: ...SSC when applied in a fixed installation using eTouch to control playbacks and select cues or any other feature in the Art SSC eTouch is designed to have no editing capability making it a fool proof i...

Page 11: ...This website has multiple pages and they are discussed in this chapter Home This is the opening page of the web interface It gives a read only overview of the settings and values Notice the status bar...

Page 12: ...modes is the EDIT mode ignores the fade hold and link values The EDIT mode is more convenient during programming the Cues Unit A DMX channel can be set between 0 minimum and 255 maximum The DMX levels...

Page 13: ...els value by 20 Capture a Cue Alternatively to programming a Cue through the CLI it is also possible to record a Cue from the DMX input port or incoming Art Net universes To capture from DMX simply co...

Page 14: ...ar to the Link field you can use the Link field to specify a cue to go back to Using both link fields you can bi directional loop by which the user could step through a set of cues by using just two b...

Page 15: ...nd quickly recall this group by clicking its button For example you can program the value of channels 1 2 3 4 6 by entering in the CLI 1 THRU 4 6 50 You can also store these channels in Group 1 by typ...

Page 16: ...ny channels change often the compression is less effective When only a few channel change a little the compression is very effective Furthermore the refresh rate setting will determine how many sample...

Page 17: ...ayback Each memory has an intensity value When the intensity is set to a value other than 0 the memory will be played back The Art SSC is capable of simultaneous playback of 4 memories When a fifth pl...

Page 18: ...ur Art SSC will respond to which signal and what tasks it will perform when triggered The show control consists of action lists and actions All the different kind of signals the Art SSC can receive ar...

Page 19: ...on a day in the week rather then a specific date The Art SSC supports this it allows to choose any combination of weekdays and time Astronomical Clock The Art SSC is equipped with an astronomical clo...

Page 20: ...MX GPI port 1 4 is converted to DMX channel 1 4 on DMX Out A GPI MIDI GPI port 1 4 is converted to Note On 1 4 messages on MIDI channel 1 GPI OSC GPI port 1 4 is converted to OSC gpiX messages GPI Art...

Page 21: ...m wide and maximum 48 per list For each Action you specify when it will be triggered and which Tasks it will perform when that trigger occurs To change the details of an action select it and press the...

Page 22: ...per Action and a maximum 128 Tasks in total When triggered the Tasks are performed in the same order as they are listed in the Action Tasks can control various elements and protocols in the Art SSC su...

Page 23: ...is useful for checking and debugging your programming The top row of buttons allows for selecting the data stream In the case of DMX or Art Net data you can use the buttons on the right to toggle betw...

Page 24: ...guish the unit in a set up with multiple Art SSCs This section also allows you to set the number of Memories in the Recorder By default this number is set to 16 If you would like to store only a few b...

Page 25: ...ges Broadcast messages do put a certain load on the network therefore it is recommended to disable Art Net when not in use Art Net transmission is switch off by default it will be enabled automaticall...

Page 26: ...mbers for outgoing UDP messages are set in the tasks at the Show Control page OSC Set the port number on which the Art SSC will listen for OSC messages in this section Also you need to fill in the add...

Page 27: ...also possible to select Internal as the time code source in this case the internal timing logic of the Art SSC is used Please see the following diagram By enabling the time code outputs for MTC OSC o...

Page 28: ...2 Home 10 HTP 16 IP address 4 iPhone 8 Kensington 3 latitude 24 Lighting Console 11 link 13 Location 24 lock 3 longitude 24 Loop 16 memories 15 MIDI 7 Monitors 22 MTC 7 OSC 8 Output Routing 24 PLAY 11...

Reviews: