160
……
191
……
192
……
223
……
224
……
255
……
15
fanction
Reset
164--191
Auto
11. Trouble Shooting
Listed below are a few common problems that you may encounter, with solutions.
◇
Unit does not work, no light output and the fan does not work;
1.
Check the power connection and main fuse.
2.
Be sure the voltage of the connector.
◇
Not responding to DMX Control;
1.
After connecting the controller, the lamp should be working. If it does not work properly, please
check if the signal plug and power cable is connected correctly.
2.
If the DMX LED is on and no response to the channel, check the address settings and the polarity
of DMX output voltage.
3.
If the signal of the product is unstable,
please check the input terminal and
circuit boards
.
4.
Try using another DMX controller.
5.
Check to see if the DMX cables run near or run alongside to high voltage cable. It may cause
damage or interference to DMX interface circuit.
◇
One of the channels is not working:
1.
The stepper motor might be damaged or the cable connected to the PCB is broken.
2.
The motor’s drive IC on the PCB might be out of condition.
12. FIXTURE CLEANING
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output.
Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or
particularly dirty surrounding can cause greater accumulation of dirt on the unit’s optics.
Clean with soft cloth using normal glass cleaning fluid.
Always dry the parts carefully.
Clean the external optics at least every 20 days. Clean the internal
optics at least every 30/60 days.
Clean the fans on the head and base every 20 days.
Disconnect the fixture before clear.