5. Safety Standard   

Users should ensure that light and installation materials are checked for regular safety checks. 

Unprofessional incorrect installation can lead to  dangerous, if  the lack of working conditions and 
professional standards, please operate the light by professionals.   

Do  not  use  the  light  if  the  working  temperature  isn’t  0-40  degrees  Celsius.  Don’t  stand  directly 

under the light when the light is installed, dismantled, moved or serviced. The operator must ensure that 
the  fixtures are securely connected. Installing the  light after professionals approving electrical 
parameters make sure that these installation must be checked at least once per year by experts. 

5.

 

Safety Standard

5.1 Hook Clamp Installation 

PG-300W-IP

 light  could  be placed on the stage or on a stand in any direction

quick lock system 

can quickly and easily remove or install a light hook. 

Note: 

5.2 Fixing Equipment 

1.Before installing fixtures must verified rigging equipment is not damaged, and can bear at least 10

times of light’s weight. Check the building can be bore at least 10 times of total weights of light, fixture, 
and cable accessories. 

2. Insert the locked hook fastener into base mounting holes horizontally, grab the handle clockwise 90

degrees fasteners, in the same way to install a second fastener, make sure the fastener is fastened under 
the light base. 

3. If truss can be lifted the equipment can be directly clamped from flight case and locked fixture base.

Then hung on the light and fixed it. Before rising the light to right height, connect the power line and 
signal line. 

Note: add a safety rope attached the light's base insurance shelf, do not connect the device handle. 

Upon  receipt  of  lamps,  please  check  if  there  is  damage  to  the  fold 

closure caused by transport, where there is transportation damage, 

please do not use this fixture, and contact us as soon as possible.

Two fixtures must be used to secure the device and tighten the clamp with 

a 1/4 button. Only the 90° clockwise rotation can lock the fastener. 

Summary of Contents for PG-300W-IP

Page 1: ...USER MANUAL PG 300W IP ...

Page 2: ...ed industrial design It fully complies with the CE standard and supports the international DMX512 signal control mode The model is fitted with 300w LED light source with strong light effect large angle water streak effect and clear gobo Meanwhile it is with 6 colors open color wheel prism water streak and zoom function It is widely used in building bridge theme park monument landscape night clubs ...

Page 3: ... PARAMETERS 5 3 SCHEMATIC LIGHTING COMPONENTS 6 4 PACKING AND SHIPPING 7 8 5 SAFETY STANDARD 8 10 6 POWER CONNECTION 11 7 LED CHIP 11 8 FUNCTIONS 11 12 9 LCD DISPLAY 13 15 10 CHANNELS 16 17 11 TROUBLE SHOOTING SOLUTION 18 12 FIXTURE CLEANING 18 ...

Page 4: ...e rather than the lamp body The product is suitable for a maximum temperature of 40 degrees Celsius when the surrounding environment is higher than 40 degrees Celsius Please do not use this product Do not touch In operation the product running very fast to prevent bumps hands If there is a problem with the operation during the show the lighting should be stopped immediately Do not perform repairs ...

Page 5: ...s Open Semi Color Effect Prism 8 Facet Rotating Prism Optical lens High precision glued optical lens combination Zoom Linear Zoom Focus Linear Focus Dimmer 0 100 Linear Dimmer Adjustment Beam 11 46 Strobe Electronic strobe 0 3 25FPS Motors 8pcs super mute sound motors Housing High temperature resistant alloy plastic plastic handle IP Rate IP66 Weight 12KG Size 330 232 513mm ...

Page 6: ...3 Schematic Lighting Components 1 dustproof tempered glass 2 head cover 3 display 4 head back cover 5 twist 6 body trestle ...

Page 7: ...o cover the light seize the aluminum handle on both sides of the equipment and put it upside down and put it into the box gently 4 Add lighting accessories after putting the light into packing box 5 It s only up to two crates stacked and is prohibited upside down 4 3 Unpacking 1 Open the packing box and packing bag 2 Seizing the equipment s handles lifting and carrying away the light from the pack...

Page 8: ...efore installing fixtures must verified rigging equipment is not damaged and can bear at least 10 times of light s weight Check the building can be bore at least 10 times of total weights of light fixture and cable accessories 2 Insert the locked hook fastener into base mounting holes horizontally grab the handle clockwise 90 degrees fasteners in the same way to install a second fastener make sure...

Page 9: ...X type connector X type connector If the external flexible cable or cord of this light is damaged please replace professional cable or cord from the manufacture or its agent Lights DMX input and output connects to a 3 5pin XLR first pin is grounded then negative signal is second pin third pin connects to the positive polarity signal the fourth and fifth is empty In order to prevent reception refle...

Page 10: ...istance 512 signal amplifier must be added DMX512 signal controller connect to the input of the amplifier first then connect to the fixture from its output couple with the terminal plug last Caution 1 Do not use two separate output connections To connect the branch a separating consecutive DMX512 signal amplifier must be used to separate 2 Please use the specialized DMX512 shielded twisted pair ca...

Page 11: ...0W IP uses domestic top LED 300W light source this LED light source concentrator integrated light source provides a very stable color temperature at 7000K color rendering index is greater than 96 and average life is more than 20 000 hours according to leds Relevant use environment Note 1 Please do not install other similar led light source otherwise it will cause safety hazards or damage the equip...

Page 12: ...lt to work synchronously and the optical lens is quickly adjusted to complete the water streak sharpness and gobo zooming function 8 5 Prism The prism wheel is equipped with 8 or 16 facet prism which can be rotated clockwise and counterclockwise at adjustable speed The color and water streak can be combined to create a variety of beautiful lighting effects 8 6 dimming and strobe 0 100 linear elect...

Page 13: ...ES NO 1 Pan Tilt 2 Color 3 Gobo 4 Dimmer 5 Zoom Prism 4 Operation DMX0 1 DMX 2 Auto 1 3 Auto 2 5 Manual Control 1 Color 0 255 2 Prism 0 255 3 Focus 0 255 4 Shutter 0 255 5 Dimmer 0 255 6 Prism Rotating 7 Water Effect Gobo 1 8 Water Effect Gobo 1 9 Automatic back to homepage after 30 seconds 6 Operation Settings 1 Dimmer Curve S Curve 1 Straight Line 2 Flat 3 4 S Curve 5 ...

Page 14: ...nels 0 10 000 255 Return 9 Switching 1 Color YES NO 2 Gobo YES NO 3 Prism YES NO Return 10 Adjustment Shutter YES NO 11 Linear Adjustment Color YES NO Return 7 Display Settings 1 Sleep 30 seconds 2 seconds 10 seconds No Sleep 2 luminance 1 10 3 Reverse display YES NO 4 Signal light Auto On Return 8 Advanced Setup 1 Fine Adjustment Value 576 2 Factory Setting 3 Copy of Fine Adjustment Info and Reco...

Page 15: ...es Confirm Cancel 11 Factory Reset Confirm Cancel 12 Continue Electronic Ballast YES NO Effect YES NO Water effect plate YES NO Return 13 Clear Programming Set Confirm Cancel Return 9 Information 1 DMX 2 Status 3 Lamp on times 4 Error Information 5 Time Remaining Hour Infinite 6 Security Setting 3 0 7 Testing Mode Return ...

Page 16: ...e from fast to slow 192 255 ticlockwise from slow to fast 2 Shutter 0 2 Power off 3 7 Power on 8 97 Shutter from slow to fast 98 101 Light off 102 126 Open pulse shuttle from fast to slow 127 151 Off pulse shutter from fast to slow 152 155 Power on 156 180 random Open pulse shuttle from fast to slow 181 205 Random closed pulse shuttle from fast to slow 206 209 Power on 210 249 Random shutter from ...

Page 17: ...5 Positive and negative reversal from slow to fast 7 Streak2 64 127 Positive reversal from slow to fast 128 191 Positive and negative reversal from fast to slow 192 255 Positive and negative reversal from slow to fast 8 PRISM 0 127 empty 128 255 PRISM 9 PRISM Rot prism rotating 0 63 prism rotating 0 720dgree 64 127 prism Positive from fast to slow 128 191 Prism negative reversal from slow to fast ...

Page 18: ...ntroller 5 Check to see if the DMX cables run near or run alongside to high voltage cable It may cause damage or interference to DMX interface circuit One of the channels is not working 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 12 FIXTURE CLEANING The cleaning of internal and external optical lenses ...