Elaflex ZVA AdBlue LV Installation And Operating Manual Download Page 15

TROUBLESHOOTING 

Flowrate too low: 

Follow the instructions to increase the flowrate in  chapter 'Calibration/ Flowrate 

Adjustment'. Ensure that the operating pressure (at the nozzle/ hose connection) is at  least 1,5  bar. 

No dispensing: 

Ensure that the operating pressure (at the nozzle/hose connection) is at  least  1,5  bar. 

ln  case of unreleased pressure in the spout -caused by improper operation'l - first try to release the 

pressure by  pushing the  EW  22  test adapter onto the spout until stop.  If this does not help,  remove 

the scuffguard,  remove the guard  and  loosen the spout screw with  EW  SK  3 (hex  key,  3 mm)  until 

liquid cornes out, see pictures below. Attention, splashes possible - wear safety glasses.  Reassembly 

in  reverse order. 

Spout untight: 

Check for mechanical damage, in this case substitute the spout.  Also check if AdBlue

® 

has crystallised in  the spout tip. ln  this case soak the nozzle spout in  a bucket of warm water. This helps 

to dissolve the crystals. 

No automatic shut-off: 

Push  EW  22  test adapter over the  nozzle spout to  override the  misfilling 

prevention, check if the flow rate  is  at minimum 3 I/min when the lever is  fully pulled  and afterwards 

in the upper latched position. If necessary, follow the instructions to increase the flowrate on  page 12. 

Premature shut-off: 

Check if AdBlue

® 

has  crystallized  in  the spout tip.  ln  this case  soak the nozzle 

spout in  a bucket of warm water. This helps to dissolve the crystals.  Ensure that the flowrate does not 

exceed  10  I/min  while the volume flow switch  is  set to  '10  I/min'  calibration  position.  If necessary, 

follow the instructions to decrease the flowrate on  page 12. 

If  dispensing is not possible due to failed dispenser heating (icing), 

first bring back the heating 

into service.  Once a sufficient operation  temperature is  reached,  dispense at  least 3-4  1 AdBlue to 

restore the full functionality. 

If  ZVA AdBlue LV still does not work properly, 

please contact Elaflex. 

*l  Please note:  multiple dispensing attempts (pulling the lever very often) without either test adapter

EW 22 or complete connection to the ISO 22241-5 tiller point lead to the formation of an  overpressure

within the nozzle. This may temporarily inhibit the dispensing. 

15 

Summary of Contents for ZVA AdBlue LV

Page 1: ...A AdBlue A AdBlue esky Strana...

Page 2: ...2 Pozn mka Ad Blue je registrovan ochrann zna ka spole nosti VDA Mo ovinov roztok je tak zn m jako AUS32 DEF nebo ARLA32...

Page 3: ...dle EN 13012 stejn jako certifikaci ATEX 0 V N mecku je podle po adavk na vodn z kony TRwS 781 povoleno pou it upev ovac ho za zen ZVA AdBlue LV pokud je tankovac pistole vybavena a provozov na s odtr...

Page 4: ...uvnit pistole P ed uveden m do provozu zatla te testovac adapt r EW 22 na v tla n potrub a na doraz aby do lo k p eklenut ochrany proti chybn mu tankov n paliva EW 22 z st v na erpac pistoli a do konc...

Page 5: ...ti sm ru hodinov ch ru i ek Po proveden prav zkontrolujte znovu m ru pr toku P padn lze tak nastavit pr tok p mo na hadicov konektor EA 075 LV nebo SSB 16 LV Za t mto elem oto te ernou clonu EW SK 3 i...

Page 6: ...ouze n kolik zb vaj c ch kapi ek by m lo vyt ct z v tla n ho potrub pot co byl odta en testovac adapt r 2 Odstra te pi ku trysky z kapaliny a odpojte testovac adapt r EW 22 od v tla n ho potrub Pouze...

Page 7: ...nebo v motorov m prostoru Dodr ujte pros m pokyny v robce vozidla Obsluha v dejn pistole je obdobn jako u b n ZVA Pro v dej mus b t v dejn pistole zcela zasunuta do plnic ho hrdla n dr e AdBlue Pot j...

Page 8: ...pad pono te v tla n potrub do kbel ku s teplou vodou abyste rozpustili krystaly Automatick vypnut nefunguje Zatla te testovac adapt r EW 22 na v tla n potrub a na doraz abyste odemkli ochranu proti ch...

Page 9: ...n datum na pistoli nap klad 16 1 tvrtlet roku 2016 Ze z ruky jsou vylou eny tankovac pistole kter byly vystaveny vn j mu opot eben nebo byly pou v ny nevhodn tekutiny a p sady N klady na v m nu a opra...

Page 10: ...OPERATING CONDITIONS ZVA AdBlue LV is suitable for the use with tiller inlets to ISO 22241 5 The nozzle is type approved to EN 13012 and ATEX certified Note The use of the lever latch is not allowed i...

Page 11: ...ressure within the nozzle This is done by overriding the misfilling prevention of the nozzle push the EW 22 test adapter onto the spout until stop EW 22 remains in this position until the end of the f...

Page 12: ...he flowrate again Alternatively the flowrate can also be adjusted at the hose connection EA 075 LV or SSB 16 LV Screw off hose connection Rotate the black orifice with tool EW SK 3 hex key 3 mm The bl...

Page 13: ...hall shut off automatically 2 Then pull the nozzle spout out of the liquid and pull off the EW 22 test adapter There should be just a few drips after removing the test adapter 1 2 Tightness While disp...

Page 14: ...e boot trunk or the angine bay Please follow your vehicle manufacturer s AdBlue refilling instructions Handling of the nozzle is similar t o conventional ZVA nozzles ln orderto dispense the nozzle mus...

Page 15: ...pter over the nozzle spout to override the misfilling prevention check if the flow rate is at minimum 3 I min when the lever is fully pulled and afterwards in the upper latched position If necessary f...

Page 16: ...elivery date cannot be established the date code on the nozzle e g 2016 means 1st quarter 2016 prevails Excluded are nozzles and parts subject to wear and tear abuse and to contamination Furthermore e...