Elaflex ZVA AdBlue LV Installation And Operating Manual Download Page 12

FLOWRATE  ADJUSTMENT 

To put the nozzle into  operation, 

adjust the actual flowrate to  5 I/min.  When  using  the  hose 

connections EA  075  LV  or SSB  16  LV,  the volume flow switch shall  be  set to the  standard  '5I/min' 

marking. Check the flowrate with the help of a calibrated vessel. 

To  adjust the flowrate to 5 I/min, turn the adjusting screw below the lever with EW  SK 3 

(hex key 3 mm): 

• To  increase the flowrate turn screw clockwise

• To  decrease the flowrate turn screw anti-clockwise

Afterwards check the flowrate again.

Alternatively, the flowrate can  also be adjusted at the  hose  connection  EA  075  LV  or SSB  16  LV: 

Screw off hose connection.  Rotate the black orifice with tool  EW  SK  3 (hex key,  3 mm).  The black 

orifice includes 4 different bore diameters to adjust the flow path (factory setting: fully open). 

After adjustment,  reattach the swivel  EA075 LV  or Safety Swivel  Break SSB  16  LV  to  the nozzle and 

check the flowrate again. 

When using hose connections without volume flow switch 

the dispenser should provide setting 

options '10 I/min'  and  '5  1/min'.  To  put the nozzle into operation please set the dispenser to  '5  I/min'. 

To  adjust the actual flowrate to '5 I/min'  please see instructions above. 

12 

Summary of Contents for ZVA AdBlue LV

Page 1: ...A AdBlue A AdBlue esky Strana...

Page 2: ...2 Pozn mka Ad Blue je registrovan ochrann zna ka spole nosti VDA Mo ovinov roztok je tak zn m jako AUS32 DEF nebo ARLA32...

Page 3: ...dle EN 13012 stejn jako certifikaci ATEX 0 V N mecku je podle po adavk na vodn z kony TRwS 781 povoleno pou it upev ovac ho za zen ZVA AdBlue LV pokud je tankovac pistole vybavena a provozov na s odtr...

Page 4: ...uvnit pistole P ed uveden m do provozu zatla te testovac adapt r EW 22 na v tla n potrub a na doraz aby do lo k p eklenut ochrany proti chybn mu tankov n paliva EW 22 z st v na erpac pistoli a do konc...

Page 5: ...ti sm ru hodinov ch ru i ek Po proveden prav zkontrolujte znovu m ru pr toku P padn lze tak nastavit pr tok p mo na hadicov konektor EA 075 LV nebo SSB 16 LV Za t mto elem oto te ernou clonu EW SK 3 i...

Page 6: ...ouze n kolik zb vaj c ch kapi ek by m lo vyt ct z v tla n ho potrub pot co byl odta en testovac adapt r 2 Odstra te pi ku trysky z kapaliny a odpojte testovac adapt r EW 22 od v tla n ho potrub Pouze...

Page 7: ...nebo v motorov m prostoru Dodr ujte pros m pokyny v robce vozidla Obsluha v dejn pistole je obdobn jako u b n ZVA Pro v dej mus b t v dejn pistole zcela zasunuta do plnic ho hrdla n dr e AdBlue Pot j...

Page 8: ...pad pono te v tla n potrub do kbel ku s teplou vodou abyste rozpustili krystaly Automatick vypnut nefunguje Zatla te testovac adapt r EW 22 na v tla n potrub a na doraz abyste odemkli ochranu proti ch...

Page 9: ...n datum na pistoli nap klad 16 1 tvrtlet roku 2016 Ze z ruky jsou vylou eny tankovac pistole kter byly vystaveny vn j mu opot eben nebo byly pou v ny nevhodn tekutiny a p sady N klady na v m nu a opra...

Page 10: ...OPERATING CONDITIONS ZVA AdBlue LV is suitable for the use with tiller inlets to ISO 22241 5 The nozzle is type approved to EN 13012 and ATEX certified Note The use of the lever latch is not allowed i...

Page 11: ...ressure within the nozzle This is done by overriding the misfilling prevention of the nozzle push the EW 22 test adapter onto the spout until stop EW 22 remains in this position until the end of the f...

Page 12: ...he flowrate again Alternatively the flowrate can also be adjusted at the hose connection EA 075 LV or SSB 16 LV Screw off hose connection Rotate the black orifice with tool EW SK 3 hex key 3 mm The bl...

Page 13: ...hall shut off automatically 2 Then pull the nozzle spout out of the liquid and pull off the EW 22 test adapter There should be just a few drips after removing the test adapter 1 2 Tightness While disp...

Page 14: ...e boot trunk or the angine bay Please follow your vehicle manufacturer s AdBlue refilling instructions Handling of the nozzle is similar t o conventional ZVA nozzles ln orderto dispense the nozzle mus...

Page 15: ...pter over the nozzle spout to override the misfilling prevention check if the flow rate is at minimum 3 I min when the lever is fully pulled and afterwards in the upper latched position If necessary f...

Page 16: ...elivery date cannot be established the date code on the nozzle e g 2016 means 1st quarter 2016 prevails Excluded are nozzles and parts subject to wear and tear abuse and to contamination Furthermore e...