background image

LUPUS2K - VOLANS2K

 - TECHNICAL MANUAL - 

090001113

[email protected]
elmospa.com

2

This product needs batteries for correct functioning. Exhausted batteries have to be delivered to dumping grounds 
authorized for battery collection. The materials used for this product are very harmful and polluting if dispersed in the 
environment.

EU DECLARATION OF CONFORMITY

DISPOSAL INSTRUCTIONS - INFORMATION FOR THE USER

FOREWORD

FOR THE INSTALLER:

Comply strictly with current standards governing the installation of electrical systems and security systems, and with the manufacturer’s 
directions given in the manuals supplied with the products.
Provide the user with full information on using the system installed and on its limitations, pointing out that there are different levels of security 
performance that will need to suit the user’s requirements within the constraints of the specific applicable standards. See that the user looks 
through the warnings given herein.

FOR THE USER:

Check the system’s operation thoroughly at regular intervals, making sure the equipment can be armed and disarmed properly.
Make sure the system receives proper routine maintenance, employing the services of specialist personnel who meet the requirements 
prescribed by current regulations.
Ask your installer to check that the system suits changing operating conditions (e.g. changes in the extent of the areas to be protected, change 
in access methods, etc...).

-------------------------------

This device has been designed, built and tested with the utmost care and attention, adopting test and inspection procedures in accordance 
with current legislation. Full compliance of the working specifications is only achieved in the event the device is used solely for its intended 
purpose, namely:

The device is not intended for any use other than the above and hence its correct functioning in such cases cannot be assured.
Consequently, any use of the manual in your possession for any purpose other than those for which it was compiled - namely for the purpose 
of explaining the product’s technical features and operating procedures - is strictly prohibited.
Production processes are closely monitored in order to prevent faults and malfunctions. However, the componentry adopted is subject to an 
extremely modest percentage of faults, which is nonetheless the case with any electronic or mechanical product.
Given the intended use of this item (protection of property and people), we invite you to adapt the level of protection offered by the system to 
suit the actual situation of risk (allowing for the possibility of impaired system operation due to faults or other problems), while reminding you 
that there are specific standards for the design and production of systems intended for this kind of application.

We hereby advise you (the system’s operator) to see that the system receives regular routine maintenance, at least in accordance with 
the provisions of current legislation, and also check on as regular a basis as the risk involved requires that the system in question is 
operating properly, with particular reference to the control unit, sensors, sounders, dialler(s) and any other device connected. You must 
let the installer know how well the system seems to be operating, based on the results of periodic checks, without delay.

Work involved in the design, installation and maintenance of systems incorporating this product should be performed only by personnel 
with suitable skills and knowledge required to work safely so as to prevent any accidents. It is vital that systems be installed in accordance 
with current legislation. The internal parts of certain equipment are connected to the mains and therefore there is a risk of electrocution 
when maintenance work is performed inside without first disconnecting the primary and emergency power supplies. Certain products include 
batteries, rechargeable or otherwise, as an emergency backup power supply. If connected incorrectly, they may cause damage to the product 
or property, and may endanger the operator (explosion and fire).

In accordance with Directive 2012/19/EU on waste electrical and electronic equipment (WEEE), please be advised that 
the EEE was placed on the market after 13 August 2005 and must be disposed of separately from normal household 
waste.

IT08020000001624

Hereby, EL.MO. S.p.A. declares that the radio equipment LUPUS2K - VOLANS2K is in compliance with Directive 2014/53/

EU. The full text of the EU declaration of conformity is available at the following Internet address: elmospa.com – registration 

is quick and easy.

Radio transmitters for wireless NG-TRX intrusion detection systems

Summary of Contents for NG-TRX LUPUS2K

Page 1: ...TECHNICAL MANUAL LUPUS2K VOLANS2K AND BROWN VERSIONS Radio transmitters for wireless NG TRX intrusion detection systems 090001113 IT08020000001624...

Page 2: ...ponentry adopted is subject to an extremely modest percentage of faults which is nonetheless the case with any electronic or mechanical product Given the intended use of this item protection of proper...

Page 3: ...tion for the roll up shutter detector and the piezo sensor The detector is fully configurable via software only the sensitivity is adjustable on the device itself The plastic housing features a design...

Page 4: ...s Blue front LED Yellow front LED used also for piezo sensor pulses visualization LED exclusion Via software application Sound signalling Built in buzzer It can be activated for alarm also in Walk tes...

Page 5: ...OPERATION VISUALIZATION AND TRANSMISSION PIEZO SENSOR AND RELATIVE TERMINAL NOT MOUNTED IDENTIFYING LABEL STUCK ON THE HOUSING SIDE IDENTIFYING LABEL STUCK ON THE HOUSING SIDE YELLOW LED FOR VISUALIZ...

Page 6: ...ol unit or on the compatible receiving device WARNING in case you use a new battery or a battery that has not been used for a long time a wrong indication of low battery may occur at first activations...

Page 7: ...of the materials used in the building construction The following pictures show correct and wrong installation positions objects that may attenuate RF signals and attenuation in some building material...

Page 8: ...he VOLANS2K transmitter is suitable for detecting impact but not for cuts and perforations METAL GRIDS AND REINFORCED CONCRETE WALLS METAL DOORS MIRRORS VIDOMO2K OR VICOMPACT2K CONTROL UNIT IR DETECTO...

Page 9: ...t to worsen the radio signal Note the maximum distance from the roll up shutter sensor can be set via software to 1 or 8 meters this is helpful in case of installation with large windows or in case yo...

Page 10: ...mounting phase 3 INSERT AND BLOCK THE CAP WITH THE MAGNET HOOK THE BOARD IN TO THE TWO INDICATED CLIPS FOLLOWING THE NUMBERING WARNING DURING THE INSTALLATION OF THE VOLANS2K SENSOR IT IS CONVENIENT...

Page 11: ...cted against removal from the mounting surface Install KSAS1013 kit green before fixing the detector base to the fixture A open pre drilled area A cut the cable connector off feed the cable from the f...

Page 12: ...S STANDARD EQUIPMENT AFTER INSTALLING THE PRODUCT INSERT THE BATTERY BETWEEN THE INDICATED TABS RESPECTING THE POLARITY DO NOT TOUCH THE BATTERY TERMINALS WITH YOUR FINGERS IN THIS PHASE 1 2AA LITHIUM...

Page 13: ...ve zones however you can immediately avoid memorizing an unused channel or you can disconnect such a channel from the browser application in order to occupy less zones The software menu can also be us...

Page 14: ...unused channel or you can disconnect such a channel from the browser application in order to occupy less zones The software menu can also be used to move the channels to different zones e g to group...

Page 15: ...y press the PROG button of the transmitter next to the magnet and keep it pressed for at least 3 seconds 7 A double beep of the internal buzzer and a double blink of the transmitter LED signal a succe...

Page 16: ...he acquired code The picture highlights the informations concerning the radio NG TRX system the firmware version and the transmitter model Activates the internal buzzer of the transmitter in alarm or...

Page 17: ...preferred channel involves the transition to an other channel if the same interference has already been detected and logged in the last 48 hours The general options selection about the 434 MHz interf...

Page 18: ...reset it will be updated at the first transmission Namely immediately after the main reset the supervision time that will be considered is the current one any devices that are not aligned within that...

Page 19: ...In idle conditions they have to take an inclination similar to that shown in the figure The distance between the two tabs should be about 25 mm if more you will have to push them inward to obtain the...

Page 20: ...POWER ON OR BATTERY REPLACEMENT 6 7 INSTALLATION 7 8 COVERAGE AND SENSITIVITY 8 9 MOUNTING 9 9 1 Protection against removal from mounting surface 11 10 ELECTRICAL CONNECTIONS 12 10 1 Board general vie...

Reviews: