background image

EN

NOTE!

The section concerning safety must be read and 

understood by everyone who uses or repairs this 

machine. The instructions describe operation and 

maintenance measures that can be performed by 

the operator. More detailed maintenance or trou-

bleshooting may only be performed by a qualified 

professional or the manufacturer. The instructions 

describe all necessary safety features and must be 

read and understood by the user before connect-

ing the machine to the electrical supply. In other 

words, the first action after delivery is to read 

through the operating instructions. 

There are symbols and warning labels on the 

machine that are mentioned in the section on 

“Safety”. If any of  the warning signs on the ma

-

chine have become damaged or worn, new signs 

must be ordered and fitted as quickly as possible in 

order to ensure the greatest possible safety when 

using the machine.

The machine may only be used for the purposes 

described in this instruction.

The manufacturer reserves the right to make 

changes.

APPLICATION AREA

The machine is intended for drying and heating 

buildings where there is a need for temporary 

heating, drying or air circulation.

the sides of Module 1. Check that these are not 

damaged or deformed. The lifting eyes are only 

designed to support the weight of  the machine 

itself.

TF 9EL EBC: 

Position the machine in its desig

-

nated place. Connect the El-Björn metal air distrib-

utor. Connect the power cable to a fused 5-pin 16 A 

socket that is protected by a residual current device.

TF 18EL EBC: 

ts designated place. Lock the 

wheels on the machine. Connect the power cable 

to a fused 5-pin 32 A socket that is protected by a 

residual current device.

TF 36EL EBC: 

Position the machine in its des

-

ignated place. Lock the wheels on the machine. 

Connect the El-Björn metal air distributor. Connect 

the power cable to a fused 5-pin 63 A socket that is 

protected by a residual current device.

TF 72EL EBC:

 Position the machine in its des

-

ignated place. Lock the wheels on the machine. 

Connect the El-Björn metal air distributor. Connect 

the power cable to a fused 5-pin 125 A socket that 

is protected by a residual current device. 

INSTALLATION

CHECK BEFORE USE

That the machine is protected by a residual cur-

rent device.

That the filter is fitted and is clean and undam

-

aged.

That cables and connectors are undamaged and in 

good condition.

That the metal air distributor is correctly connect-

ed and unobstructed.

That the wheels are locked.

Check that the machine is positioned at least 0.5 m 

away from the wall.

That the machine always stands on a firm, level 

surface.

INSTALLATION 

In order to achieve the best drying and heating 

performance, the machine should be positioned 

as centrally in the room as possible. The machine 

must run continuously in order to achieve optimal 

results. Minimum distance from wall: 0.5 m. The 

machine should only be used upright, with its 

wheels/feet at the lowest point. If  the machine is 

to be suspended, use the 4 lifting eyes provided on 

Summary of Contents for TF 18EL

Page 1: ...TF 9EL TF 18EL TF 36EL TF 72EL EBC This product is only suitable for well insulated areas or occasional use Manual EN...

Page 2: ...ical inlet outlet Do not expose it to high tempera tures oil or sharp edges Make sure the machine is standing on a firm level surface Important Do not try to lift the machine using the carrying handle...

Page 3: ...sing electrical machinery basic safety regulations shall always be followed in order to reduce the risk of fire electric shocks burns or other personal injury Read the instructions before starting the...

Page 4: ...36EL TF 72EL 1 x filter with additional pre filter for extended life TF 9EL Module 2 Inlet fuses and temperature humidity sensors are well protected beneath overhang Removable cover on top for electri...

Page 5: ...se Cancel 1 On Off 2 Back 3 Press for 3 sec onds to Log out Pause for 30 min Switch off Current temperature Relative humidity Signal strength Log in authority level A Administrator S Service U User Ma...

Page 6: ...e available Log out Pause drying fan for 30 minutes Switch off CHANGING THE DEFAULT SETTING TO HEAT EVENT 1 To log in press and hold the tick button for 1 second the window below will appear 2 Use the...

Page 7: ...display within 60 seconds you will be logged out automatically 4 To change the default settings press the up arrow up or down arrow to choose a setting The chosen setting will then be highlighted in o...

Page 8: ...wer cut Power cord failure Fuse has tripped Electrical fault in fan Frost guard water temperature below critical level risk of heat exchanger freezing The fan stops if the water temperature drops belo...

Page 9: ...127 5 kg 41 5 77 5 8 5 180 kg 72 96 5 11 5 Noise level 61 54 62 57 dB A 68 63 dB A 69 63 dB A Rated current 13A 27A 57 A 110 A Rated voltage 3N 400V 3N 400V 3N 400 V 3N 400 V Encapsulation class IP 44...

Page 10: ...l air distrib utor Connect the power cable to a fused 5 pin 16 A socket that is protected by a residual current device TF 18EL EBC ts designated place Lock the wheels on the machine Connect the power...

Page 11: ...ine is turned off prior to filter replacement or before the machine is moved See instructions for display DEINSTALLATION Turn off the machine according to the display instructions This extends the lif...

Page 12: ...Module 1 When the machine is not in use store it indoors where it is dry and there is no risk of freezing SCRAPPING Take the machine to a recycling station according to state or local regulations WAR...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...SE 334 21 Anderstorp Sweden 46 0 371 588 100 info elbjorn se www elbjorn com 201012 El Bj rn UK LTD Unit 2 Oyester Park 109 Chertsey Road West Byfleet GB Surrey KT14 7AX Phone 44 01483 729 348 E mail...

Reviews: