Cleaning

•   Always replace the filter after use.

•   Clean externally with a mild soap solution and 

a damp cloth. The display can be cleaned with 

glass cleaner and a soft cloth.

•   Air-blow the inside of the machine carefully, 

then wipe with a damp cloth.

•   Never use inflammable or combustible sol

-

vents near the machine.

NOTE!

All repairs to electrical parts must be per-

formed by a qualified professional or the 

manufacturer.

TROUBLESHOOTING/CHECK LIST

The machine does not start

•   Check that the fuses in the nearest electrical 

cabinet are intact.

•   Check whether the residual current device in 

the nearest electrical cabinet has tripped.

•   The machine has overheated and cannot be 

restarted until the temperature has dropped.

•   Check whether the fuses in the machine have 

tripped. These are located beneath the inlet 

behind the fuse cover.

TRANSPORTATION/STORAGE

The machine must always be transported upright. Before transporting the machine, fix the air distrib

-

utor in its lowered position if  necessary. During transportation, the machine must be anchored to the 

transport vehicle. The machine should only be lifted using the 4 lifting eyes on the sides of Module 1.

When the machine is not in use, store it indoors where it is dry and there is no risk of  freezing.

SCRAPPING

Take the machine to a recycling station according to state or local regulations. 

WARRANTY

El-Björn AB’s products and deliveries are regulated by Standard Agreement NL 09. Under these provi

-

sions, El-Björn AB is responsible for faults arising within one year from delivery.

The provisions of  NL 09 also apply for professional parties who register according to the instructions 

below, although with the following modification:

El-Björn AB is liable for faults arising within five years after delivery; this only applies to products 

registered on the website.

In other respects, the provisions of  NL 09 apply.

To obtain this extended warranty, you must register within 14 days from the date of purchase of  the 

products.

The machine emits too little air

•   Check that the air distributor/vents are not 

blocked.

•   Check that the air inlet and filter are not 

clogged.

•   See the display instructions.

There is no hot air supply

•   Check that the correct drying program has 

been selected. 

•   Check whether the fuses have tripped. These 

are located beneath the inlet behind the fuse 

cover.

•   Check whether the overheating protector has 

tripped. The display will show a red warning.

If  this fault occurs, contact a qualified professional 

or the manufacturer.

Summary of Contents for TF 18EL

Page 1: ...TF 9EL TF 18EL TF 36EL TF 72EL EBC This product is only suitable for well insulated areas or occasional use Manual EN...

Page 2: ...ical inlet outlet Do not expose it to high tempera tures oil or sharp edges Make sure the machine is standing on a firm level surface Important Do not try to lift the machine using the carrying handle...

Page 3: ...sing electrical machinery basic safety regulations shall always be followed in order to reduce the risk of fire electric shocks burns or other personal injury Read the instructions before starting the...

Page 4: ...36EL TF 72EL 1 x filter with additional pre filter for extended life TF 9EL Module 2 Inlet fuses and temperature humidity sensors are well protected beneath overhang Removable cover on top for electri...

Page 5: ...se Cancel 1 On Off 2 Back 3 Press for 3 sec onds to Log out Pause for 30 min Switch off Current temperature Relative humidity Signal strength Log in authority level A Administrator S Service U User Ma...

Page 6: ...e available Log out Pause drying fan for 30 minutes Switch off CHANGING THE DEFAULT SETTING TO HEAT EVENT 1 To log in press and hold the tick button for 1 second the window below will appear 2 Use the...

Page 7: ...display within 60 seconds you will be logged out automatically 4 To change the default settings press the up arrow up or down arrow to choose a setting The chosen setting will then be highlighted in o...

Page 8: ...wer cut Power cord failure Fuse has tripped Electrical fault in fan Frost guard water temperature below critical level risk of heat exchanger freezing The fan stops if the water temperature drops belo...

Page 9: ...127 5 kg 41 5 77 5 8 5 180 kg 72 96 5 11 5 Noise level 61 54 62 57 dB A 68 63 dB A 69 63 dB A Rated current 13A 27A 57 A 110 A Rated voltage 3N 400V 3N 400V 3N 400 V 3N 400 V Encapsulation class IP 44...

Page 10: ...l air distrib utor Connect the power cable to a fused 5 pin 16 A socket that is protected by a residual current device TF 18EL EBC ts designated place Lock the wheels on the machine Connect the power...

Page 11: ...ine is turned off prior to filter replacement or before the machine is moved See instructions for display DEINSTALLATION Turn off the machine according to the display instructions This extends the lif...

Page 12: ...Module 1 When the machine is not in use store it indoors where it is dry and there is no risk of freezing SCRAPPING Take the machine to a recycling station according to state or local regulations WAR...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...SE 334 21 Anderstorp Sweden 46 0 371 588 100 info elbjorn se www elbjorn com 201012 El Bj rn UK LTD Unit 2 Oyester Park 109 Chertsey Road West Byfleet GB Surrey KT14 7AX Phone 44 01483 729 348 E mail...

Reviews: