background image

Page  10 

 

 

 
 
 

 

Maintenance and cleaning

 

Type

 

Description

 

Before cleaning  Turn off the burner on the control ( stop ) Wait for 15 min. so  the 

burner gets cold before anything is demounted. Take care that 
wires are not broken or pulled during cleaning. 

The hopper 

Refill the hopper before it is totally empty. If the auger is not 
covered with pellets irregularities will occur in the operation, as the 
burner do not get the right amount of pellets. Wood pellets contain 
sawdust, and it might pile up by the auger depending on how much 
dust there is in the pellets. (quality of the pellets). Because of this it is 
recommended to empty the hopper from time to time. By much dust 
there is a risk that the amount the auger feeds will change and this 
might cause operation stop. 

Ashpan 

The  ashpan  must  be  emptied  before  it  is  totally  full,  before  the 
burner cannot get rid of the ash. This can vary from boiler type to 
boiler type and  type of wood  pellets.  The  ash  can  be  used  in  the 
garden as compost. 

The burner 

According to need 

take out the burner by loosening the two 

handles on each side of the burner. 
The air vents which are placed in the herd are checked. They must 
not be blocked. Especially the vents under the inlet of the auger are 
important, as this is where the hot air comes in from the igniter and 
ignites the pellets. If they are blocked, you will get a slow or no 
ignition. 
The oblong holes on the left side are just as important, as this is 
where the photo sensor sees if there is fire in the burner tube.  If 
they are blocked the boiler will turn off. 
You take a steel brush and clean inside the burner tube, until the 
air vents are clean. If necessary they can easily be cleaned with a 
Ø 4-5 mm screw or drill. 
If slag has occured in the burner tube due to impurities in the 
pellets, it might be necessary to take the burner out to clean it. This 
is done by demounting of the front plate of the burner and the 
three bolts on the burner tube, and then it can easily be lifted up. 
All holes in the burner must be clean to give full passage of air. 

Summary of Contents for EkoHeat 1500

Page 1: ...are up dating Page 17 Technical specifications Page 18 Warranty Page 19 CE Marking Page 20 23 Test of approval Page 24 Marks of approval The pellet boiler from Ekopower has been tested by Dansk Teknol...

Page 2: ...not be more than 0 5 m long and must always be rising If the flue pipe extend more than 0 5 meter or if bendings are mounted then it must always be insulated The draught in the chimney must be stable...

Page 3: ...a time Calibration of the auger must be done before start up of the boiler as it then will not obtain the ultimate combustion and thus have a lower efficiency Press Menu user settings adjust calibrat...

Page 4: ...Boiler temperature 40 80 60 Here you set the wanted boiler temperature Should not be below 60 and always 10 higher than the set point of the shunt valve Fuel 0 Kilogram pellets which are added per hou...

Page 5: ...r is needed The temperature of this must be set under VVB priority Summer operation must be activated to do this and this can be checked by the appearance of a sun in the graphics on the front page De...

Page 6: ...this will run when the temperature of the boiler is above set point and stops when this is below again Ekopower recommends to set pump stop at 55 and the boiler temperature at 65 by engagement of summ...

Page 7: ...ill destroy the thread for the spindle Efficiency for flue suction 0 100 100 Here you can adjust how much air need to be added in proportion to efficiency in percent You can adjust per 10 These number...

Page 8: ...oiler temperature rises before the boiler stops and waits for a temperature drop The boiler starts again when the boiler temperature is below 45 degrees Max efficiency 20 100 60 The boiler can be set...

Page 9: ...ifferent flags as a symbol of which language you want on the boiler Menu Self Testing Here you can choose which type of boiler you have 900 1500 2500 4000 Test boiler is only for Ekopower authorised t...

Page 10: ...of wood pellets The ash can be used in the garden as compost The burner According to need take out the burner by loosening the two handles on each side of the burner The air vents which are placed in...

Page 11: ...ensor and the ash plate can be taken out and the slag can be removed Photo sensor Once a month check the photo sensor for dirt on the eye Pull it carefully out of its holder and clean the glass part w...

Page 12: ...Page 12 Electrical chart of the control...

Page 13: ...sive pipe pocket on the return water Draught stabilizer To be used by too much draught or by fluctuating draught to give a more even draught in the chimney Connection kit A connection kit is used betw...

Page 14: ...gnition error The amount of pellets for ignition is too small or too big The calibration might be incorrect The boiler must be calibrated If this does not help adjust the amount of pellets for ignitio...

Page 15: ...lation of slag on the ash plate Clean the ash plate for slag The screw stick is not greased with aluminium paste or the screw block is worn out Grease the screw stick with aluminium paste Change the s...

Page 16: ...Then carefully lift out the controller 3 The USB flash drive is inserted in the USB port app on the middle of the printed circuit board 4 Now press MENU in the display 5 Then press FITTERS SETTINGS an...

Page 17: ...s 74 liters 104 liters Min chimney draught 0 1 mBar 0 1 mBar 0 1 mBar 0 1 mBar Electrical connection 230V 60Hz 1 5A 340 Watt 230V 60Hz 1 5A 340 Watt 230V 60Hz 1 5A 340 Watt 230V 60Hz 1 5A 340 Watt Fue...

Page 18: ...the warranty D Ekopower reserve the right to send an external service company This can only be done by Ekopower The installer dealer who have no written agreement from Ekopower will not get any work...

Page 19: ...t EK OHEAT 900 EKOHEAT 1500 EK OHEAT 2500 EK OHEAT 4000 M tdi ine DndRie 3 1 CE stuvl 1 EN 3ffi 5 ffiM ng oo ilm fir solii mls hind M Ld i llltDin i lti cilly stDhd rom naJ hei 11 Cl llp1i a I to 300h...

Page 20: ...Page 20...

Page 21: ...Page 21...

Page 22: ...Page 22...

Page 23: ...Page 23 We do hope that you have got a good profit from this manual Should you have further questions please do not hesitate to contact us at post ekopower dk...

Reviews: