11. PNEUMATIC CONNECTION
11.1. Connecting to the compressed air outlet
The pressure line (2) is attached to the
compressed air outlet (1) on the
compressor.
Connect the drain hose (1) to the
condensate vessel on compressors with
dryers.
Fig. 8: Connecting to the compressed air outlet
Route the pressure hose through the opening in the back wall of the cabinet (Fig. 10) on
compressors in cabinet.
11.2. Connecting the cabinet pressure gauge to the compressor
Remove the plug (1) from the threads
(2) on the pneumatic block of the
compressor
Connect the cabinet pressure gauge
hose to the threaded fitting
Fig. 9: Connecting the cabinet pressure gauge to the compressor
11.3. Connecting the condensate vessel
Connect the condensate drain hose to the condensate collection vessel on compressors in
cabinet.(Fig. 10)
Summary of Contents for DK50 2V S
Page 1: ...DK50 PLUS M DK50 2V M User manual Benutzerhandbuch N vod na pou itie...
Page 2: ......
Page 4: ...CONTENTS 5 INHALT 49 OBSAH 94...
Page 15: ...PRODUCT DESCRIPTION 02 2020 15 NP DK50 PLUS 2V A 3_02 2020 MD Fig 3 Cabinet...
Page 25: ...INSTALLATION 02 2020 25 NP DK50 PLUS 2V A 3_02 2020 MD Fig 6 Changing door direction...
Page 44: ...PRODUCT MAINTENANCE NP DK50 PLUS 2V A 3_02 2020 MD 44 02 2020 Fig 21 230V A B...
Page 59: ...PRODUKTBESCHREIBUNG 02 2020 59 NP DK50 PLUS 2V A 3_02 2020 MD Abb 3 Kompressorgeh use...
Page 69: ...INSTALLATION 02 2020 69 NP DK50 PLUS 2V A 3_02 2020 MD Abb 6 ndern der T r ffnungsrichtung...
Page 89: ...PRODUKTWARTUNG 02 2020 89 NP DK50 PLUS 2V A 3_02 2020 MD Abb 21 230V A B...
Page 104: ...POPIS V ROBKU NP DK50 PLUS 2V A 3_02 2020 MD 104 02 2020 Obr 3 Skrinka...
Page 114: ...IN TAL CIA NP DK50 PLUS 2V A 3_02 2020 MD 114 02 2020 Obr 6 Zmena otv rania dver...
Page 133: ...DR BA V ROBKU 02 2020 133 NP DK50 PLUS 2V A 3_02 2020 MD Obr 21 230V A B...
Page 141: ......
Page 142: ......
Page 143: ......