FIREFRONT
This fire is supplied with a particular style of firefront. Use of the firefront will ensure an adequate
airflow under the firebed for the correct functioning of this appliance.
Compliance with safety standards cannot be guaranteed if another style of front is used.
CLEARANCES TO COMBUSTIBLES
A combustible shelf may be fixed to the wall above the fire, providing that it complies with the
dimensions given below.
A non-combustible shelf may be fitted to within 10mm of the top edge of the fireframe.
Combustible materials, such as wood, may be fitted to within 100mm (4in) of either side of the
frame of the appliance, providing the forward projection does not exceed 100mm (4in).
Any combustible side walls must be at least 500mm to the side of the radiant heat source.
As with all heating appliances, any decorations, soft furnishings, and wall coverings (i.e. flock,
blown vinyl and embossed paper) positioned too close to the appliance may discolour or scorch.
VENTILATION
No purpose provided ventilation is normally required for this appliance.
The requirements of
other appliances operating in the same space or room, and the results of a spillage test must be
taken into consideration when assessing ventilation requirements, this will have been carried out
by your CORGI registered installer.
For Republic of Ireland, ventilation may be required, see IS 813, ICP3, IS 327, and any other rules
in force.
OPERATING INSTRUCTIONS (manual versions)
The pilot is visible through the left hand side of the front coal strip. Push in and turn the control
knob to the SPARK position, and hold there for a few seconds. Continue turning anti-clockwise
through the spark click to the PILOT light position, ensuring the pilot has lit. If not, return the
knob clockwise, and repeat.
When the pilot lights after the spark, keep the knob depressed for
approximately ten seconds. Now release the knob and the pilot
should stay alight. If not, repeat ignition. If the pilot is extin-
guished
during use
, wait three minutes before repeating the igni-
tion procedure.
To achieve the HIGH setting, push the control knob in slightly and
continue turning anti-clockwise to the high position. The main
burner should light after a few seconds.
To decrease the setting to LOW, turn the control knob clockwise
to the low setting.
To turn to the PILOT position from the HIGH or LOW positions, press the control knob in, and
return to the pilot position and release.
To turn the fire OFF, keep the knob pressed in, return to the off position and release.
2
Maximum depth of shelf Minimum distance from inside edge of
fire frame to underside of shelf
100mm (4in)
745mm (29 1/4 in)
150mm (6in)
845mm (33 1/4 in)
203mm (8in)
895mm (35 1/4 in)
2.0
3.0
4.0
5.0
©
2009 Focal Point Fires plc.