OPERATING THE FIRE (manual versions)
The pilot is visible through the left hand side of the front coal strip. Push in and turn the control
knob to the SPARK position, and hold there for a few seconds.
Continue turning anti-clockwise through the spark click to the PILOT light position, ensuring the
pilot has lit. If not, return the knob clockwise, and repeat.
When the pilot lights after the spark, keep the knob depressed for approximately ten seconds.
Now release the knob and the pilot should stay alight. If not, retry ignition. If the pilot is extin-
guished during use, wait three minutes before repeating the ignition procedure.
To achieve the HIGH setting, push the control knob in slightly and
continue turning anti-clockwise to the high (large flame) position.
The main burner should light after a few seconds.
To decrease the setting to LOW, turn the control knob clockwise
to the low setting.
To turn to the PILOT position from the HIGH or LOW positions,
press the control knob in, and return to the pilot position and
release.
To turn the fire OFF, keep the knob pressed in, return to the off
position and release.
A safety interlock prevents re-ignition of the pilot flame until the thermocouple has cooled suffi-
ciently to allow the magnetic valve unit to reset itself.
OPERATING THE FIRE (remote control versions)
The gas valve has two control knobs ;
Turn the main burner control (shown on left
hand side of control valve) knob fully anti-
clockwise.
Turn ignition knob (shown on right hand side
of control valve) slightly left towards the igni-
tion position until reaching the stop, press
down and hold for a few seconds until pilot
gas is flowing.
Continue pressing down the knob while turn-
ing further to the left to activate the piezo
spark, continue to hold the knob down for a
further 10 seconds after the pilot has been
lit. If the pilot does not light repeat the pre-
vious steps.
Upon lighting the pilot and after the further 10 seconds, release the knob and turn further to the
left to the ON position. The main burner will light and be controlled in accordance with the main
burner control knob setting. Adjust the main burner control knob to the desired setting.
If the pilot is extinguished during use of the fire, you must wait three minutes before repeating
the ignition procedure.
To turn the main burner OFF whilst keeping the pilot flame lit, turn the ignition control knob to
the pilot position then only the pilot will remain lit.
To shut the fire off completely, press the ignition control knob down and continue turning to the
right from the pilot position to the OFF position.
A safety interlock prevents re-ignition of the pilot flame until the thermocouple has cooled suffi-
ciently to allow the magnetic valve unit to reset itself.