PV Blocks system
Page 62
4. SPECIFICATIONS
PV Base pack (items 1-3)
1. PV Base communication module
2.
Power supply module
3.
PV Link computer module
IV / MPP pack (IV/MPP Load module)
Supply Voltage
24 VDC
Communication interface
RS 485 serial communication
Operating temperature range
-25ºC – 70ºC
Maximum number of PV blocks
32
Maximum number of IV/MPP blocks
8
Supply Voltage
24 VDC
Power
5 A /120 W
Input voltage range
100 VAC – 240 VAC / 50-60 Hz
Operating temperature range
-25ºC – 70ºC
Supply Voltage
24 VDC
Operating temperature range
-25ºC – 70ºC
Operating system
Linux / web interface
Memory
4 GB
Data storage
32 GB SSD
Communication
WAN / Local (3 ethernet ports)
Operating modes
MPPT(P&O), Voltage Biasing, Open Voltage, Short cir-
cuit
Supply Voltage
24 VDC
Communication interface
RS 485 serial communication
Operating temperature range
-25ºC – 40ºC
Max Load IV measurement
600 W
Max Load MPP load
600 W
Cooling
Forced ventilation
Temperature protection
Delta T=60ºC ()
ADC
Simultaneous measurement of current voltage, 24 bits
Voltage range / Resolution
1 – 200V / 1mV (No true zero)
Voltage Accuracy
+/- 10mV
Current range / Resolution
0 – 20A / 1mA
Current accuracy
+/- 10mA
IV points
100
IV sweep time
200ms – 30 seconds
IV sweep
Isc – Voc or Voc - Isc
Operating modes
MPPT(P&O), Volatge Biasing, Open Voltage, Short cir-
cuit
Summary of Contents for PV Blocks MP-1000S
Page 1: ...PV Blocks PV Evaluation system Instruction Manual Powered by ReRa Solutions...
Page 11: ...PV Blocks system Page 11 Figure 1 1 PV Blocks configuration...
Page 13: ...PV Blocks system Page 13 Figure 1 3 12V power block...
Page 35: ...PV Blocks system Page 35 Press the New button to create a new PV Module...
Page 51: ...PV Blocks system Page 51...