4.4.5 Specification of the accumulator
Battery
Charger
Rated power
:
24V
Rated capacity
:
350Ah(EK13A)
400Ah(EK15A)
Input
:
AC115/230
50Hz
Output
:
DC24V50A
Rated power
:
24V
Rated capacity
:
350Ah Li-ion
(EK15A-189)
Input
:
AC115/230
50Hz
Output
:
DC24V50A
Uninsulated terminal poles on the accumulator should be protected with an
insulated cover. When connecting the accumulator and socket, make sure to stop
the forklift and put the switch at position “0”.When replace or install the
accumulator, make sure the accumulator is fixed securely in battery box.
4.4.6 Storage, transportation and installation of the accumulator
The forklift must be parked on the level ground steadily. To prevent short
circuit, naked cable ends and the terminal posts should be covered with
insulated covers. When pulling out the accumulator, properly arrange removed
accumulator's connectors and cables without blocking access of the accumulator.
When install or remove the accumulator with a crane, make sure the load
capacity is sufficient (weight of the accumulator is marked on both the
nameplates of the accumulator and the stacker.) The crane must pull vertically to
prevent the battery box from being damaged. The hooks of the crane should be
safe and secure. Never let the hooks fall on an individual battery .
—
Press emergency stop switch and turn the power supply switch to OFF
position
—
Remove the connectors of accumulator cables.