en│13
Step
Instruction
10.
Enter the required values in the input fields.
NOTICE
For a system setup with several converters (
ekey multi
variant 2), input field
FS1
must always be used for the
finger scanner assignment.
This means that the serial number of the finger scanner
being assigned and the corresponding facility code must be
entered in the
FS1
input line for each converter.
11.
Click on
Save
to apply the settings.
Click on
Cancel
to discard the settings.
Configuration of the converter is complete. The converter is ready for
installation and implementation.
Below you will find configuration examples for the different system setup
variants.
variant
ekey home
In this example, the 26-bit Wiegand format was adapted to the third-
party Wiegand system. The OEM code and bit lengths were configured.
Fig. 7:
Configuration example:
variant
ekey home
variant 1
ekey multi
In this example, the serial numbers of the 4 finger scanners being
assigned and the facility codes in the converter have been entered. This
Configuration
examples