Convection gas oven _ rev. 2__________________________ MODD. EKF 711G UD – EKF 664G UD – EKF 616G UD
_________________________________________________________________________________________ page. 5
Note 1:
The information provided in this manual are valid only for the oven’s models listed in the cover
and for the country whose initials are therein indicated with the category of membership.
For European countries whose initials are present in the data plate on the left side panel (see
Fig. 1), the operating instructions will be provided in the official language with functional
adaptations to the country (as the additional injector for gas available and its conditions of
supply).
Note 2:
These instructions apply only if the EU country code is given on the nameplate of the oven. If
the code does not appear, you should refer to the technical instructions which will provide
necessary instructions regarding the adaptation of the unit to the conditions of use of other
non-EU countries.
Note 3:
This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance
shall not be made by children without supervision. “
Note 4:
The power cable used must not have lower characteristics than: rubber insulated type H07RN-F
with diameter of 3 x 1,5 mm
2
. If connection to the electrical mains is permanent, a multi-core
protective switch of adequate capacity must be installed, with contact opening distance of the
overvoltage category III (4000 V).
Note 5:
If the supply cable is damaged then it must be replaced by the manufacturer or by your
technical support or by a qualified person to avoid any risk.
Note 6:
The water pressure must be in the range of 100 to 200 kPa (1,0 – 2,0 bar).
The appliance is equipped with flexible hose (1.5 metres) with threaded female fittings
¾
” and
relevant gaskets. Old gaskets must not be reused.