Connection  to  the  gas  supply  line  must  be  made  by  using  rigid  or  flexible  pipes  (maximum 
length 1,5m) , exclusively in metal, with diameters in proportion to the power of the appliance 
and the length of the pipe route. Make sure that the pipe does not pass close to the hot areas 
and that it is not subjected to torsion and traction stresses. Install a rapid ON/OFF tap between 
the gas mains and each appliance, in a position facilitating tap opening and shutting operations. 
After installing the appliance, run a tightness test on the entire gas circuit, using a leak-detector 
spray or other non-corrosive foam generating substances (do not use flames for this operation). 
The unions of the copper pipes must be made by using mechanical couplings without seals. 

2.8 

 

Electrical connection 

Connection to the electrical mains must be made according to the current legal regulations. 
Before making the electrical  connection, make sure that the voltage and frequency shown on 
the rating-plate match those of the electrical supply system and that the latter is provided with 
an efficient earth connection. The power cable used must not have lower characteristics than: 
rubber  insulated  type  H07RN-F  with  diameter  of  3  x  1,5  mm

2

.  If  connection  to  the  electrical 

mains is permanent, a multi-core protective switch of adequate capacity must be installed, with 
contact opening distance of the overvoltage category III (4000 V).  
The yellow/green earth wire must not be disconnected by the switch. 
If  the  supply  cable  is  damaged  then  it  must  be  replaced  by  the  manufacturer  or  by  your 
technical support or by a qualified person to avoid any risk. 
The  appliance  must  be  part  of  an  equipotential  system  -  this  connection  is  obtained  with  the 
stop  screw  marked  with  the  symbol    located  at  the  rear.  The  diameter  of  the  equipotential 
wire must be 2,5 mm

2

When  the  appliance  is  operating,  the  supplied  voltage  must  not  deviate  from  the  nominal 
voltage value of ± 10%. 
To replace the cable, cut  off electrical power, and access  the terminal board by removing the 
oven  rear  panel.  Locate  the  cables  so  that  the  earth  conductor  is  the  last  to  detach  from  its 
terminal in the event of reverse pulling. Use an electrical cable with characteristics not below to 
those mentioned above. 
If the power supply cable is damaged it must be replaced by the manufacturer or their technical 
support service, or in any case by a person with similar qualifications, to prevent any risk. 

2.9  Connection to water mains 
The oven must be supplied with softened drinking water (see the respective signal next to the 
connection solenoid-valve), with a hardness value of 0,5 to 5°F (it is mandatory using a water 
softener to reduce the formation of scaling inside the boiler). The water pressure must be in the 
range of 100 to 200 kPa (1,0 – 2,0 bar). If the water pressure exceeds 2,0 bar, install a pressure 
reducer device upstream. If the pressure is below 1,0 bar, use a pressure pump to increase the 
level. 
The connection to the water supply is done using the 

¾

” threaded solenoid valve on the back 

(at  the  bottom)  of  the  appliance  (see  fig.  3),  fitting  a  mechanical  filter  with  a  cut-off  cock 
(before connecting the filter, allow a certain  amount of water to flow out in order to remove 
any waste from the pipe). 
Warning 
Any damage caused by limescale or other chemicals contained in the water are not covered by 
warranty.  

2.10  Connection Water outlet  
A drain pipe comes out of the rear of the appliance (see Fig.1) to drain the cooking chamber.  
This pipe must be connected to piping with 30 mm inner diameter (DN 30) resistant to steam 
temperature (90°C-100°C).  
To  avoid  choking  the  pipe  should  be  stiff  and  there  should  be  no  "elbows"  along  the  drain 
path. The pipe must also maintain constant slope (min. 5%) along its entire length (the length 
considered  is  that  of  the  appliance's  drain  pipe  at  the  drain  point  and  must  not  exceed  2 
metres).  The  drain  piping  must  be  conveyed  into  an  open  floor drain  (Fig.2);  otherwise,  there 

Summary of Contents for EKF 616G UD

Page 1: ...MANUAL MODD EKF 711G UD EKF 664G UD EKF 616G UD rev 2 CATEGORY II2H3 GB 0705 TECNOEKA S r l Via Marco Polo n 11 35010 Borgoricco Padova Italy Tel 39 049 9300344 39 049 5791479 Fax 39 049 5794387 www tecnoeka com E mail info tecnoeka com ...

Page 2: ...bility directive 2014 30 UE TECNOEKA Srl hereby declares that the above mentioned products meet the requirements of the following harmonized standards EN 60335 1 EN 60335 2 102 EN 55014 1 EN 55014 2 EN 61000 3 2 EN 61000 3 3 EN 62233 TECNOEKA Srl hereby declares that the above mentioned products also meet the requirements of the following directives Gas Appliances directive 2009 142 CE General pro...

Page 3: ...tion 2 9 Connection to water mains 2 10 Water outlet 2 11 Thermal breaker safety devices 3 Start up for installation technician 3 1 Check of nominal thermal capacity 3 2 Check of connection pressure 3 3 Adaptation to other gas 3 4 Injector replacement and adjustment of primary air 4 User instructions 4 1 General information 4 1 1 Residual risks 4 2 How to use the control panel 4 2 1 Control panel ...

Page 4: ...________ 6 Maintenance 6 1 General information 6 2 Changing the lighting lamp in the cooking chamber 6 3 Changing the door seal 6 4 Cleaning the fans 6 5 Resetting the thermal breaker safety device 6 6 Possible faults 6 7 Wiring layout 7 TECHNICAL ASSISTANCE AND ORIGINAL SPARE PARTS 7 1 Spare parts list 8 Informations to the consumers 9 The Warranty 10 Availability and supply of spare parts ...

Page 5: ...se of other non EU countries Note 3 This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user ma...

Page 6: ...on on safe use installation and maintenance The purpose of this manual is to provide information to operators on the essential prescriptions and criteria to ensure their own safety and prolong the oven s operating life This manual must be read by all personnel authorised to work on the machine before it is started up It must be stored together with the machine for all future consultation If the ma...

Page 7: ... mbar MK NO RO SE SI UA Fig 1 DE Dieses Gerat muß nach geltenden Vorschriften angeschlossen und darf nur in einem gut belufteten Raum betrieben werden Bitte beachten Sie vor Inbetriebnahme des Gerates die Gebrauchs und Wartungsanleitung FR L appareil doit être raccordé conformément aux normes en vigueur et il ne doit être installé que dans locaux bien aérés Faire attention aux instructions relativ...

Page 8: ...150 mm L 1 m G30 28 30 mbar fume load 29 83 g s fume temperature 169 2 C fume pressure 2 9 Pa Main injector diameter G30 G31 190 1 100 mm G20 280 1 100 mm Primary air bush adjustment G30 G 31 16 mm G20 10 mm Table 1 The noise level of the appliance in operation is less than 70 dB A 2 General instruction for installation technician The installation technician must make sure that start up conforms t...

Page 9: ...openings if possible it should be placed under an exhaustion hood ensuring complete evacuation of burned gasses produced during baking Locate the oven on a table or similar support We advise to use the support given by the manufacturer otherwise you must consider the weight of the oven Never on the floor The maximum working height referred to the highest surface level must be 1 6 meters from the f...

Page 10: ...ume of air required for the combustion is not obstructed in any way by objects placed under or around the unit The Italian UNI 8723 rule in force since October 2010 Gas systems for the hospitality professional communities and similar provides the safety requirements on the conformity of the systems ventilation and exhaust fumes combustion and baking products It is valid for the Italian national te...

Page 11: ... GLAND FOR POWER SUPPLY 10 WARNING HOT SURFACE 11 DO NOT OBSTRUCT VENTS 16 GAS INLET THREADED JOINT 1 2 Fig 3 Dimensions in mm 2 7 Gas connection Before installing make sure that the oven is designed for use with the available gas If it is not consult paragraph Adaptation to other gas or contact the manufacturer s technical assistance service Connection to the gas mains must be made according to t...

Page 12: ...rear The diameter of the equipotential wire must be 2 5 mm2 When the appliance is operating the supplied voltage must not deviate from the nominal voltage value of 10 To replace the cable cut off electrical power and access the terminal board by removing the oven rear panel Locate the cables so that the earth conductor is the last to detach from its terminal in the event of reverse pulling Use an ...

Page 13: ...ng which might accidentally occur inside it In the event of tripping the device interrupts power supply to the appliance and the incoming gas to the burner 3 START UP for installation technician 3 1 Check of nominal thermal capacity The nominal thermal capacity must be verified by an authorised technician or by the gas supply Body observing the information in this use manual This check must be per...

Page 14: ...e burner and the primary air adjuster If you do not have the necessary spare parts contact the manufacturer s technical assistance service Adaptation must be effected by qualified personnel Consult the technical specifications in table 1 and 3 and then replace the main injector and adjust primary air 3 4 Injector replacement and adjustment of primary air Fig 7 WARNINGS Before you attempt this oper...

Page 15: ...truct the burned gasses outlet or the oven flue and do not place any objects over these points Check regularly the efficiency of the extraction unit the exhaust pipes and the building flue no soot for instance Survey the oven while it is in operation Shut the gas and water ON OFF taps upstream and disconnect electrical power when you have finished using the oven This appliance must be exclusively ...

Page 16: ...rol panel 4 2 1 Control panel Control knobs Fig 8 Fig 9 Fig 10 End of cooking programming knob Control thermostat knob Automatic humidifier knob Switching on off The oven is switched on by rotating the end of cooking programmer to the symbol or at the chosen cooking time It is switched off by turning the knob to zero Cooking time setting Turn the end of cooking programmer knob to the chosen cookin...

Page 17: ...eated The Reset button must be pressed after at least 5 6 seconds after No Gas lights on Warning At first ignition of the burner of the oven for possible presence of air in the pipeline that feeds the device it may be necessary to repeat the operation of thermal release of the oven press several times the button reset 4 3 First ignition The oven can be used for the first time only after the chambe...

Page 18: ... 4 5 2 Convection cooking dry heat The heating elements heat the dry air inside the cooking chamber This heated air is evenly distributed by the high speed of the fans This gives an even temperature throughout the cooking chamber and even cooking even when the oven is full This means that different types of food can be cooked on the various shelves as long as they need the same cooking temperature...

Page 19: ...tainless steel on the external walls on the fan casing do not spray it through the fan grids and on the glass inside the door leave the product to work for approximately 20 minutes with the door closed turn the oven on to 70 80 C run a cycle with maximum steam for around 15 minutes when the cycle is complete turn the oven off leave the cooking chamber to cool down and rinse well Dry with a soft cl...

Page 20: ... its life and assures proper functionality Any maintenance operation on the appliance must only be done by highly qualified personnel trained in the operations to be performed Before performing any maintenance on the appliance the power supply must be disconnected act on the safety magnetic circuit breaker located upstream of the appliance and let it cool down The components that might require mai...

Page 21: ...tion to water mains Check the connection to water mains Cut off cock closed Check the cut off cock Blocked water inlet filter Clean the filter Damaged water inlet solenoid Contact a qualified technician to repair the solenoid Door closed steam comes out of the seal Seal not fitted correctly Check the seal fitting Damaged seal Contact a qualified technician to repair the seal Handle prong loosened ...

Page 22: ...nd of cooking programmer U Automatic humidifier T 230 12V transformer L Lighting lamp MI Door microswitch Filtro Anti noise filter E Water solenoid valve F Fuse IM Direction inversing element V1 V2 Radial motorised ventilators V3 Tangential motorized ventilator C1 C2 Capacitors CE Gas card R Relay E1 Ignition electrode E2 Detection electrode IR RESET GAS button switch S1 No flame indicator light S...

Page 23: ... 01202980 Reset button 00010300 Red indicator 00005460 Door microswitch 00010510 Capacitor 01201030 Water solenoid valve 01203180 Gas solenoid valve 01201810 Anti noise filter 01202010 Power supply terminal board 01200720 Oven ventilation motor 01202600 Oven cooling motor 01202330 Direction inversing element 01201040 Safety thermostat 01202780 Relay 01200820 Transformer 00012590 Fuse holder 000058...

Page 24: ...parts 8 inadequate or careless maintenance of the product in contrast with the user s handbook supplied with the product 9 damages caused by fire natural disasters and accident as well as by any cause not attributable to TECNOEKA SRL In addition painted or enamelled parts knobs handles mobile or removal plastic parts light globes glass parts refractory stones electronic parts and any accessory par...