Convection gas oven _ rev. 2__________________________ MODD. EKF 711G UD – EKF 664G UD – EKF 616G UD
_________________________________________________________________________________________ page. 21
6.5 Resetting the thermal breaker safety device
This device is accessed by removing the left side and/or back of the appliance. The device is
reset by pressing hard the relevant button.
6.6 Possible faults
Type of fault
Cause
Corrective action
Control panel
completely off (the
oven does not work)
Incorrect electric connections to the mains
Check the mains connection
No mains voltage
Restore mains voltage
Thermal break safety device tripped
Reset the thermal break safety device
Cooking cycle set: the
oven does not work
Door open or ajar
Close the door
Damaged magnetic sensor
Contact a qualified technician to repair the
sensor
Automatic humidifier
ON: no steam is
produced in the
cooking chamber
Incorrect connection to water mains
Check the connection to water mains
Cut-off cock closed
Check the cut-off cock
Blocked water inlet filter
Clean the filter
Damaged water inlet solenoid
Contact a qualified technician to repair the
solenoid
Door closed: steam
comes out of the seal
Seal not fitted correctly
Check the seal fitting
Damaged seal
Contact a qualified technician to repair the seal
Handle prong loosened
Contact a qualified technician to repair the
prong
The oven does not
cook evenly
One of the motors is blocked or turns slowly
Contact a qualified technician to repair the
motor
The motors do not go into reverse
Contact a qualified technician to repair the
motor
Heating element not powered or is damaged
Contact a qualified technician to repair the
element
Lighting lamp in the
cooking chamber does
not work
Damaged lamp
Change the lamp
Damaged lamp feeder
Contact a qualified technician to repair the
feeder
The thermo safety
device turns on in
continuous
Device damaged
Contact a qualified technician to repair the
feeder
Regulating thermo state damaged
Contact a qualified technician to repair the
feeder