21
Note
• If you select "HLG", you must set "HLG System Gamma".
PQ Option
Settings: "300cd/
㎡
Clipping" / "500cd/
㎡
Emulation" / "1000cd/
㎡
Emulation" / "4000cd/
㎡
Emulation" / "10000cd/
㎡
Emulation"
Areas with brightness equal to or greater than the value set here are displayed as clipping
or emulation at this setting value for the PQ signal that is input to the monitor.
• "300cd/
㎡
Clipping"
Setting used to check the display of monitor with maximum brightness of 300 cd/m
2
.
Input video level of 637 (10 bits) or more is clipped.
• "500cd/
㎡
Emulation"
Setting with which the image is properly displayed when monitor brightness is set to 500
cd/m
2
. If the monitor brightness is less than 500 cd/m
2
, all gradients are emulated.
• "1000cd/
㎡
Emulation"
Setting with which the image is properly displayed when monitor brightness is set to
1000 cd/m
2
. This setting is used for a temporally check because this monitor cannot
display 1000 cd/m
2
. All gradients are emulated.
• "4000cd/
㎡
Emulation"
Setting with which the image is properly displayed when monitor brightness is set to
4000 cd/m
2
. This setting is used for a temporally check because this monitor cannot
display 4000 cd/m
2
. All gradients are emulated.
• "10000cd/
㎡
Emulation"
Setting with which the image is properly displayed when monitor brightness is set to
10000 cd/m
2
. This setting is used for a temporally check because this monitor cannot
display 10000 cd/m
2
. All gradients are emulated.
Note
• This can be set when "PQ" is specified for "Gamma (EOTF)".
• You can check the areas where clipping or emulation occurs. For more information, see
.
• For relation between input and output for each setting, see
Setting and Display Method of PQ
HLG Option
Settings: "Off" / "HLG300"
When selecting "HLG300" with the brightness set to 300 cd/m
2
for the HLG signal input to
the monitor, any areas exceeding 300 cd/m
2
will be clipped. Selecting "Off" will not clip
these areas.
Note
• This can be set when "HLG" is specified for "Gamma (EOTF)".
HLG System Gamma
Settings: "1.0" – "1.5"
Adjust the system gamma value for the HLG signal that is input to the monitor.