10. Troubleshooting
Fault
Possible causes
Remedies
The motor fails to
start
a) The capacitor is defective
b) The connectors have become
separated from the motor or the
capacitor
c) The mower is standing in high
grass
d) The mower housing is clogged
e) Safety switch is not inserted
f) Battery is not correctly inserted
a) Have repaired by the Customer
Service Center
b) Have repaired by the Customer
Service Center
c) Start in low grass or on an area that
has already been mowed; change
the cutting height if necessary
d) Clean the housing so that the blade
moves freely
e) Insert safety switch (see 6.)
f) Remove the battery and reinsert
(see 5.)
The motor perfor-
mance drops
a) The grass is too high or too damp
b) The mower housing is clogged
c) The blade is severely worn
d) Battery performance decrea-
sing
a) Correct the cutting height, change
the electronics setting
b) Clean the housing
c) Replace the blade
d) Check the battery performance
and charge the battery if necessary
(see 5.)
Cutting is irregular
a) The blade is worn
b) Wrong cutting height
a) Replace or resharpen the blade
b) Correct the cutting height
Notice! For protection, the motor is equipped with a thermal switch which cuts out when the
motor is overloaded and switches on again automatically after a short cooling period
Anl_GE_CM_33_Li_Kit_Solo_SPK7.indb 27
10.10.2016 16:14:29
Summary of Contents for GE-CM 33 Li Kit
Page 4: ... 4 9 10 11 12 A 1 13 14 3 3 8 B A 8 Anl_GE_CM_33_Li_Kit_Solo_SPK7 indb 4 10 10 2016 16 14 22 ...
Page 5: ... 5 15 1 2 3 4 5 6 Anl_GE_CM_33_Li_Kit_Solo_SPK7 indb 5 10 10 2016 16 14 26 ...
Page 172: ... 172 Anl_GE_CM_33_Li_Kit_Solo_SPK7 indb 172 10 10 2016 16 14 45 ...
Page 173: ... 173 Anl_GE_CM_33_Li_Kit_Solo_SPK7 indb 173 10 10 2016 16 14 45 ...
Page 174: ...EH 09 2016 01 Anl_GE_CM_33_Li_Kit_Solo_SPK7 indb 174 10 10 2016 16 14 45 ...