TROUBLESHOOTING
•
Controller is beeping
o
It is alarming because a control stage has ended in the process (e.g. Pre-Heat/Mash In,
Mashing, Boiling, Cooling) and human intervention is required to proceed. Press the
Alarm button to cancel the alarm.
•
Turning the Control Panel On/Off
o
Use the dedicated on/off switch to turn the Control Panel On/Off.
•
Control Panel does not turn on
o
Please ensure that the power inlet cable is inserted securely, and the supplying power
socket is turned on.
o
If using an RCD as recommended, please ensure that it is activated and not in TEST
mode. It will not provide power in this state.
o
Please check that the fuses (accessible via the external fuse holders) have not blown.
Ensure that the system is disconnected from mains electricity whilst removing or
replacing the fuses.
•
Brew taking a long time to reach Set Temperatures
o
It can be normal for it to take a reasonable length of time to preheat to temperatures.
How long will depend on your system
–
how much water, and how powerful the heating
elements are
–
it can be typical to find an increase in temperature of 1°C every 1 minute.
This will differ depending on the ambient temperature, and if you have the lid on the
vessels being heated on or off. Also, the higher the temperature, the more heat losses
will occur
–
it will be slower to transition from 90°C to 100°C, than 20°C to 30°C. Adding
insulation to the vessels may help, or adding a more powerful heating element.
•
Error Indicators
o
If you see an unusual temperature reading, this may be due to an incorrectly placed,
incorrectly connected or damaged temperature probe.
o
If the
Measured Temperature display is showing ‘ERR’, this means there is a problem
with the temperature probe. Please ensure that it is connected correctly. It may also
provide an error code
–
e.g. ‘ERR1’.
Please communicate this to Support if you cannot
resolve yourself.
o
If a Temperature Probe error occurs whilst a Stage is actively being controlled, the
system will automatically go into Pause mode to prevent overheating. The timer display
will indicate
‘FLT’ rather than ‘PAUS’ on the bottom half to indicate this. Until this error
is resolved, you will be unable to unpause the control process for safety reasons.
o
Please note any information and communicate it to Support if necessary.
•
Pump does not operate
o
This may be due to the pump inlet getting clogged by debris. Please check that the filter
for the inlet is not covered and remove any debris.