-4-
Electrical Adjustments
Group/
Item
Item Name
Function
Initial
range Note
7 Temp C Warning (Normal)
Temp. C to judge the Temp Error at
Normal (Lamp)
60
60
0-100
8 Temp B-A Warning (Normal)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
0-100
9 Temp C-A Warning (Normal)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
0-100
10 Temp A Warning (Eco)
Temp. A to judge the Temp Error at
Eco (Room)
46
46
0-100
11 Temp B Warning (Eco)
Temp. B to judge the Temp Error at
Eco (Panel)
62
62
0-100
12 Temp C Warning (Eco)
Temp. C to judge the Temp Error at
Eco (Lamp)
60
60
0-100
1 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
0-100
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
0-100
15 Temp A Warning Offset
(Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
5
0-100
16 Temp B Warning Offset
(Temp)
15
0-100
17 Temp C Warning Offset
(Temp)
15
0-100
18 Temp B-A Warning Offset
(Temp)
100
0-100
19 Temp C-A Warning Offset
(Temp)
100
0-100
20 Temp A Warning Offset
(Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X min-
ute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
15
0-100
21 Temp B Warning Offset
(Time)
0
0-100
22 Temp C Warning Offset
(Time)
0
0-100
2 Temp B-A Warning Offset
(Time)
40
0-100
24 Temp C-A Warning Offset
(Time)
40
0-100
Group
254
Fan control range Setting (temp./Voltage)
Normal
Ceiling
0 High Fan Control Min Temp
Temp Senser Control Start/End Temp.
at High
8
8
20-100
1 High Fan Control Max Temp
42
42
20-100
2 High Fan1 Min
Fan voltage value at High (unit: 0.1V)
95
95
0-255
High Fan1 Max
15
15
0-255
4 High Fan2 Min
85
85
0-255
5 High Fan2 Max
10
10
0-255
6 High Fan Min
75
75
0-255
7 High Fan Max
77
77
0-255
8 High Fan4 Min(LAMP1)
-
-
0-255
9 High Fan4 Max(LAMP1)
-
-
0-255
10 High Fan5 Min(LAMP1)
-
-
0-255
11 High Fan4 Max(LAMP1)
-
-
0-255
12 Normal Fan Control Min Temp
Temp Senser Control Start/End Tem.p
at Normal
8
8
20-100
1 Normal Fan Control Max
Temp
42
42
20-100
14 Normal Fan1 Min
Fan voltage value at Normal (unit:
0.1V)
80
80
0-255
15 Normal Fan1 Max
125
125
0-255
16 Normal Fan2 Min
75
75
0-255
17 Normal Fan2 Max
120
120
0-255
18 Normal Fan Min
70
70
0-255
19 Normal Fan Max
70
70
0-255
20 Normal Fan4 Min
-
-
0-255
21 Normal Fan4 Max
-
-
0-255
22 Normal Fan5 Min
-
-
0-255
2 Normal Fan5 Max
-
-
0-255
24 Eco Fan Control Min Temp
Temp Senser Control Start/End Tem.p
at Eco
6
6
20-100
25 Eco Fan Control Max Temp
42
42
20-100
26 Eco Fan1 Min
Fan voltage value at Eco (unit: 0.1V)
65
65
0-255
27 Eco Fan1 Max
115
115
0-255
28 Eco Fan2 Min
70
70
0-255
29 Eco Fan2 Max
110
110
0-255
0 Eco Fan Min
5
5
0-255
1 Eco Fan Max
5
5
0-255
2 Eco Fan4 Min(LAMP1)
-
-
0-255
Eco Fan4 Max(LAMP1)
-
-
0-255
4 Eco Fan5 Min(LAMP1)
-
-
0-255
Summary of Contents for LC-WB42N
Page 67: ... 67 IC Block Diagrams FA7701 DDC Control IC7841 FA7703 Fan Power Control IC7811 Component2 ...
Page 68: ... 68 IC Block Diagrams MP2106 DC DC Converter IC5721 IC8018 IC8019 FA5502 P F Control IC601 ...
Page 70: ... 70 IC Block Diagrams L3E07111 LCD Driver Gamma Correction IC401 LM4889 Audio Output IC5031 ...
Page 72: ... 72 IC Block Diagrams STR Z2156 Power OSC IC651 TE7783 Parallel I O Expander IC1802 ...
Page 73: ... 73 IC Block Diagrams MP2307 DC DC Conventer IC5860 IC5842 ...
Page 113: ...KY7 WB42N00 113 Mechanical Parts List ...
Page 114: ... KY7BC July 2009 Japan 2009 Eiki Internatinal Inc A key to better communications ...
Page 132: ...A16 PCB_KY7AC NO DATA ...