-59-
Electrical Adjustment
Grp / No. Item
Function
Range
Initial
Note
4
Press Sensor Log
0: Calibration executed correctly
10: Out of Range Offset Min.
20: Out of Range Offset Max.
99: Calibration not excuted
-
99
250
Fan Voltage Adjustment
0
Fan 1 Min Adjust (DAC)
DAC Output for Fan Voltage adj.
Adjust Tolerance between DAC and Fan Volt.
*Lamp Mode: Eco
0-255
20
* Fan voltage adj.
1
Fan 1 Max Adjust (DAC)
0-255
240
* Fan voltage adj.
2
Fan 2 Min Adjust (DAC)
0-255
20
* Fan voltage adj.
3
Fan 2 Max Adjust (DAC)
0-255
235
* Fan voltage adj.
4
Fan 3 Min Adjust (DAC)
0-255
20
* Fan voltage adj.
5
Fan 3 Max Adjust (DAC)
0-255
240
* Fan voltage adj.
6
Fan 4 Min Adjust (DAC)
0-255
15
* Fan voltage adj.
7
Fan 4 Max Adjust (DAC)
0-255
230
* Fan voltage adj.
8
Fan 5 Min Adjust (DAC)
0-255
15
* Fan voltage adj.
9
Fan 5 Max Adjust (DAC)
0-255
215
* Fan voltage adj.
10
Fan 6 Min Adjust (DAC)
0-255
15
* Fan voltage adj.
11
Fan 6 Max Adjust (DAC)
0-255
215
* Fan voltage adj.
12
Fan 7 Min Adjust (DAC)
0-255
15
* Fan voltage adj.
13
Fan 7 Max Adjust (DAC)
0-255
240
* Fan voltage adj.
252
Fan Option
1
Safety Switch
Safety Application use
0-6
0
2
Fan Manual Switch
Fan Manual SW (0: Auto 1: Manual)
0-1
0
3
Fan1 Manual Voltage
Manual Adjustment Mode (0.1V)
*Effective only when Manual SW is 1.
0-255
100
4
Fan2 Manual Voltage
0-255
100
5
Fan3,4 Manual Voltage
0-255
100
6
Fan5 Manual Voltage
0-255
100
7
Fan6 Manual Voltage
0-255
100
8
Fan7 Manual Voltage
0-255
100
9
Fan8 Manual Voltage
0-255
100
10
Angle Data A
Angle Data A (Read only)
-
-
11
Angle Data B
Angle Data B (Read only)
-
-
12
Press Data
Air Pressure Data (Read only)
-
-
253
Fan Temp Error Setting
(Memorized)
Normal
Ceiling
Top
Bottom
5
Temp A Warning (Normal)
Temp A (Room) to judge the Temp Error at Normal
30-100
47
47
47
47
6
Temp B Warning (Normal)
Temp B (Lamp) to judge the Temp Error at Normal
30-100
80
80
80
80
7
Temp C Warning (Normal)
Temp C (Panel) to judge the Temp Error at Normal
30-100
68
68
68
68
8
Temp B-A Warning (Normal)
Temp B - A (Filter Clogged) to judge the Temp Error at Normal
0-100
50
50
50
50
9
Temp C-A Warning (Normal)
Temp C - A (Filter Clogged) to judge the Temp Error at Normal
0-100
32
32
32
32
10
Temp A Warning (Eco)
Temp A (Room) to judge the Temp Error at Eco
30-100
47
47
47
47
11
Temp B Warning (Eco)
Temp B (Lamp) to judge the Temp Error at Eco
30-100
80
80
80
80
12
Temp C Warning (Eco)
Temp C (Panel) to judge the Temp Error at Eco
30-100
68
68
68
68
13
Temp B-A Warning (Eco)
Temp B - A (Filter Clogged) to judge the Temp Error at Eco
0-100
50
50
50
50
14
Temp C-A Warning (Eco)
Temp C - A (Filter Clogged) to judge the Temp Error at Eco
0-100
32
32
32
32
15
Temp A Warning Offset (Temp)
Temp Warning Offset (Temp)
0-100
13
16
Temp B Warning Offset (Temp)
0-100
13
17
Temp C Warning Offset (Temp)
0-100
13
18
Temp B-A Warning Offset (Temp)
0-100
13
19
Temp C-A Warning Offset (Temp)
0-100
13
20
Temp A Warning Offset (Time)
Time Warning Offset (Time)
0-40
3
21
Temp B Warning Offset (Time)
0-40
3
22
Temp C Warning Offset (Time)
0-40
3
23
Temp B-A Warning Offset (Time)
0-40
3
24
Temp C-A Warning Offset (Time)
0-40
3
Top
30°
330°
150°
210°
Bottom
Ceiling
Normal
254
Fan Control Range Setting
(Temp/Spinning)
Normal
Ceiling
Top
Bottom
16
Normal Fan Control Min Temp
Temp Sensor Control Start/End Temp St Normal
20-100
31
31
31
31
17
Normal Fan Control Max Temp
20-100
38
38
38
38
Summary of Contents for LC-HDT700
Page 97: ...97 IC Block Diagrams ISL51002 A D Converter IC2201 M62393 DAC IC7801...
Page 99: ...99 IC Block Diagrams PW392 Scaler IC301 PW610 Keystone IC2301...
Page 100: ...100 IC Block Diagrams TE7783 I O Expander IC4801...
Page 103: ...103 Mechanical Parts List KY2 HDT70000 Shutter assembly M08...
Page 149: ...Key No Part No Description Key No Part No Description KY2 HDT70000 149 Electrical Parts List...
Page 150: ...KY7BL Nov 2011 Japan 2011 Eiki Internatinal Inc A key to better communications...