-56-
Electrical Adjustment
Grp / No. Item
Function
Range
Initial
Note
70
ADC Device Select for Analog PC 0 = ISL51002, 1 = PW392 AFE
0 - 1
0
71
ADC Device Select for Component 0 = ISL51002, 1 = PW392 AFE
0 - 1
0
72
Component/RGB Auto SW
0: Disable 1: Enable
0 - 1
1
80
Destination
Language Set at Shipping 0:English
1
:Japanese
0 - 1
0
95
Flicker 1
0: Disable 1: Enable
0 - 1
0
96
Flicker 2
0 - 15
8
100
Disable Auto Picture Control
0 : Normal operation 1 : Auto Picture Control Off
0 - 1
Initial: 1 Shipping 0
110
Monitor Output during Cooling
0: On 1: Off
0 - 1
0
112
Monitor Out Link with Video Mute 0: Not link 1: Link
0 - 1
1
120
HDMI Cont at Standby
0: Not control 1: Allow to control
0 - 1
1
130
Logo Countdown time
0: 30 sec. 1: 20 sec.
0 - 1
0
140
Offset Add Status
0: Not use Offset addition
-
0
Read only
141
Offset Change
Apply offset value when the value is set to 10.
0 - 10
0
142
Offset Value
Offset value at Shutdown temp.
-
10
Read only
143
Executed times of Offset Add
-
0
Read only
144
Canceled time of Offset Add
-
0
Read only
170
Power Mgmt Shutdown time
unit: hour
1 - 24
3
180
CcaTargetLinkedChange
"YCM" lenked function on Color matching Target change
0 - 1
1
201
Option (Signal)
0
FrameLock Option
0: Off for PC signals
1: Off for AV signals
3: Normal
4: Normal
0 - 4
4
1
Dither Enable
0: Disable 1: Enable
0 - 1
0
3
Field Sens Invert Enable
0: Disable 1: Enable
0 - 1
0
205
Spread Spectrum
0
Enable
0: On 1: Off
0 - 1
1
1
Ratio
0 to 300
0 - 300
200
2
Frequency
200 to 500
1 - 500
350
210
Lamp Contorl
0
Dimmer SW
0:Auto 1:Manual
0 - 1
0
1
Manual Control
Lamp Power Manual Control (DIMMER_CTRL_LEVEL
0(Dark)~15(Bright))
0 - 15
0
19
DIMMER_LEVEL_AUTO
Current Y Level (Read only)
-
-
Read only
20
DIMMER_LEVEL_NORMAL
Dim Level at Normal
0 - 15
15
21
DIMMER_LEVEL_ECO
Dim Level at Eco
0 - 15
0
23
VOLTAGE_LEVEL
Lamp Voltage (Read only)
-
-
Read only
220
Projector Error Log
0
Warning_Log_1
Latest Error log
0 - 32767
0
:
:
:
:
:
49
Warning_Log_50
50th Error log
0 - 32767
0
50
Warning_Log Reset
Log is cleared when the value is set to 10.
0 - 10
0
235
Shutter
0
PRE_MOTION
Shutter Warm - up Operation (0: Yes, 1: No)
0 - 1
Initial: 1 / Shipping: 0
1
CMP_TRM
Chattering Detecting Term
0 - 32767
7000
2
OUT_DLY_TRM
Output Term
0 - 32767
15000
3
CMP_CHK_CNT
Count of Information Sync
0 - 15
0
4
OPEN_DLY
Open Output Delay
0 - 63
0
5
CLOSE_DLY
Close Output Delay
0 - 63
0
6
Position Check Time
Position Check Time
1 - 255
50
8
Enable Close Cmd
Shutter Close Command 0: Disable 1: Enable
0 - 1
1
9
Speed Control
Shutter Speed
0 - 255
0
10
Shutter Management Upper Time Shutter Manement Time for Upper limit
180 -999
480
240
Flow Calibration
0
Flow Calibration Exe
Flow Sensor Offset Calibration Start calibration when the value
is set to 1.
0 - 1
0
* Wind sensor calibra-
tion.
1
Flow Calibration Error Log
Log of Calibration Error (Read only)
255: Not Calibration
0: No Error
10: 1st Calibration Not Stable Airflow
11: 1st Calibration Out of Range
20: 2nd Not Stable Airflow
21: 2nd Out of Range
100: 10th Calibration Not Stable Airflow
101: 10th Calibration Out of Range
-
255
2
Clog Check Enable
Filter Clogged Detection by Flow Sensor (0: Disable, 1: Enable)
0 - 1
Initial: 0 / Shipping: 1
4
Time Limit Auto Scroll Enable
Auto Scroll for Manimum Time (o: Disable 1: Enable))
0 - 1
1
Summary of Contents for LC-HDT700
Page 97: ...97 IC Block Diagrams ISL51002 A D Converter IC2201 M62393 DAC IC7801...
Page 99: ...99 IC Block Diagrams PW392 Scaler IC301 PW610 Keystone IC2301...
Page 100: ...100 IC Block Diagrams TE7783 I O Expander IC4801...
Page 103: ...103 Mechanical Parts List KY2 HDT70000 Shutter assembly M08...
Page 149: ...Key No Part No Description Key No Part No Description KY2 HDT70000 149 Electrical Parts List...
Page 150: ...KY7BL Nov 2011 Japan 2011 Eiki Internatinal Inc A key to better communications...