![ei3 Amphion S14-H Green Box User Manual Download Page 14](http://html1.mh-extra.com/html/ei3/amphion-s14-h-green-box/amphion-s14-h-green-box_user-manual_2369016014.webp)
Amphion User Guide
Page 14 of 26
Note: In a typical arrangement, all machine devices need to be
on the same network as “To Machine” interface of the S14-N
or S14-C.
1. Configuration using a USB drive
When an S14-H and an S14-N need to be configured for the same
facility network, it is recommended to first configure and install the
S14-H, then configure and install the S14-N.
To configure an S14, follow these steps:
1.
Obtain the correct “.ei3”
configuration file for your S14. Contact
your ei
3
administrator to get the file.
2. Save the file onto an empty, FAT 32 formatted USB drive.
3. Power off the Amphion by removing the power terminal.
4. Insert the USB drive into the USB slot of the Amphion S14
5. Power on the Amphion
6. Wait up to 4 minutes to see the Success Pattern, then remove
the USB drive. The Amphion will automatically restart after the
USB drive is removed.
•
Success Pattern - all four LEDs will flash on at the same time,
once per second.
•
Failure Pattern – the LEDs will flash in an “X” pattern
Note: The files are digitally signed by ei
3
Corporation to protect
against tampering.
It is important that you do not change the contents
of this file in any way!
!