6  Troubleshooting 

 

System faults are reported and logged in the monitoring system.  All fault logs are also accessible remotely by your installer.   
 
IMPORTANT! 
Contact your system installer as recommended below if any of the following conditions are present on the front 
display of the inverter panel. 

 
 

PCS indicator status 

Definition 

Service light ON in grid mode 

System is prevented from normal operation due to internal fault. Notify service personnel. 

Service light ON in backup mode  

If the system faults into service in backup operating mode, there may be an overload condition 
which prevents the system from operating safely.  If the battery SOC is greater than 20% (one or 
more Green battery status LEDs), reduce the load by shutting off circuits in the backup electrical 
panel, then press and hold the service button 5 seconds to resume backup power operation.  If the 
battery SOC is less than 20%  (SOC Led is yellow), do not attempt to resume backup operation until 
sunlight is present to provide a solar charge of the battery. 

All panel lights flashing 

System is attempting to communicate with the battery modules.  Notify service personnel if this 
condition persists more than 30 minutes. 

All panel lights OFF after service button 
wake command 

This indicates loss of both AC And DC sources to the PCS. 

Online monitoring system not accessible 

Check the internet connection.  If connection is via wi-fi, reboot wireless router, and make sure login 
user and password have not been changed since time of original installation. 
Check power to the Evolve energy management system via the orange indicator light on the right 
side of the panel.  Note:  the energy management system may lose power after an extended grid 
outage where there is not enough solar generation to maintain battery system power. 
Note: monitoring system servers may occasionally be down for service.  If first attempts are not 
successfully, try again the following day before contacting your installer. 
 

 

7 Installer Checklist 

 

Following the completion of your energy storage system installation, ensure your installer has provided you with the following 
information for your personal records. Note that we may ask you for this information in the event you need to make a warranty 

claim: 
 

 

Record of purchase, including date of installation, installer name and contact details. 

 

Copy of the electrical permit. 

 

Serial numbers for Battery System cabinets (PCS & Battery). 

 

EMS gateway UID – this is the unique identifier of your EMS gateway that connects to your internet service. 

 

Further to the information provided above, ask your installer to identify the following within your system installation: 

 

Location of circuit breakers, and if applicable, installed emergency disconnect switches in case an emergency shutdown 

of the equipment is required.  

 

Location of the backup electrical panel, including a list and identifier of each circuit within the panel.  

 

Record of all loads tested at the time of installation.  

 
 
 

 
 

 

Summary of Contents for Evolve 0513

Page 1: ...Eguana Evolve Model Evolve 0513 DO 68025 Evolve Owner s Manual ...

Page 2: ...hock serious injury or death Operating the product in a way that it was not intended can also result in permanent damage to the product This manual applies to the following products Evolve 0513 Energy Storage System Warranty The Eguana Evolve includes a 10 year standard warranty with performance pro rating for the battery modules Please review the warranty statement included with your product IMPO...

Page 3: ...GENCY 1 1 3 ENVIRONMENTAL PROTECTION 2 2 INTRODUCTION 3 2 1 OVERVIEW 3 2 2 SYSTEM MONITORING ACCOUNT SETUP 4 3 OPERATION 4 3 1 LED DISPLAY INDICATORS 4 3 2 SERVICE BUTTON 5 4 BACKUP POWER OPERATION 5 5 MAINTENANCE 5 6 TROUBLESHOOTING 6 7 INSTALLER CHECKLIST 6 ...

Page 4: ... to the installed location In case of fire When safe use a fire extinguisher suitable for use including A B and C dry chemical fire extinguishers or carbon dioxide extinguishers Do not use type D extinguishers In case of flooding Stay out of water if any part of the system or wiring is submerged Do not attempt to operate batteries that have been submerged in water even after they have been dried I...

Page 5: ...trical panel Ensure proper electrical grounding in accordance with code requirements CAUTION Both AC and DC voltage sources are terminated inside this equipment Each circuit must be disconnected before servicing Risks of Damage The PCS is compatible with the LG Chem battery model EM048126P3S7 only Do not attempt to connect any other battery to the system Do not connect any other loads directly to ...

Page 6: ...ram below shows a typical layout of an AC coupled solar plus storage system Your system may be installed in a manner differently than shown above In addition in accordance with your local electrical code your installer may have included dedicated emergency disconnect switches for your battery and solar systems Consult your system installer regarding the application and installation setup of your s...

Page 7: ...s present operating conditions 3 1 LED Display Indicators The display panel provides indication of the following Battery status state of charge System operating mode out of Service Indicator To conserve energy the LEDs will turn off after 5 minutes from being activated They can be re activated by pressing the service button Indicator Status Display type Color Battery Status State of charge L R 5 L...

Page 8: ...er in the home will be interrupted for up to four seconds before backup power generation commences As a result of this interruption a desktop or portable UPS is recommended if continuous uninterrupted operation is desired for any sensitive electronic equipment In the event that there is not enough solar generation to maintain battery operation in an extended duration grid outage the battery system...

Page 9: ... connection is via wi fi reboot wireless router and make sure login user and password have not been changed since time of original installation Check power to the Evolve energy management system via the orange indicator light on the right side of the panel Note the energy management system may lose power after an extended grid outage where there is not enough solar generation to maintain battery s...

Reviews: