background image

 

 
 

 

 

3.2 Service Button 

 

 

The service button can be used to wake the LED display, and either put the system into or out of service mode, as well as cycle 

through various operating modes.   
 

IMPORTANT! In the event that the system has gone out of service, please consult your installer for guidance.  Depending on the 
nature of the service fault, your installer may advise you to reset the system on your own, or schedule a service visit. 
 

 

4  Backup Power Operation 

 

This system will provide backup power to dedicated electrical circuits within the home via a permanently wired electrical sub-panel, 

referred to as the backup panel.  The power source is limited in power rating and duration, both of which are dependent on the 
nature of the loads connected to the system, and the available solar supply.  This system is designed to reliably provide power to a 
refridgerator, home lighting, home electronics, and small appliances.   

 
IMPORTANT!  Surge rated loads (compressor and motor type loads) may greatly reduce the power output capability of the battery 

system, and cause premature overload conditions.  Equipment of this type that is connected to the backup panel should be 
inspected and tested regularly as per manufacturer suggested schedules.  Do not attempt to add loads of this type to the backup 
panel without consulting your installer.  Permanent damage to the battery system and/or your equipment may occur if exposed to 

chronic overloading cycles. 
 

IMPORTANT!  Portable extension cords connected to a backup circuit should be limited to 10 meters.  Do not attempt to power 
loads to outbuildings while in backup mode. 
 
NOTE: While the battery system does provide grid quality backup power (pure sine wave) following a grid outage,  the power in the 
home will be interrupted for up to four seconds before backup power generation commences.  As a result of this interruption, a 
desktop or portable UPS is recommended if continuous, uninterrupted operation is desired for any sensitive electronic equipment. 

 
In the event that there is not enough solar generation to maintain battery operation in an extended duration grid outage, the battery 

system will automatically shutdown to a standby state with a minimum operating reserve, and attempt to restart at the beginning of 
the next solar charge cycle.  During the standby state, there will no longer be any backup power available.  This cycle will repeat 
until, a) the grid power returns, or b) the battery depletes to a hibernation state, where no backup power is available.  In the event 

that the battery reaches hibernation, the grid power must be available to restart the battery system.   
 
IMPORTANT! This product does not support automatic gas generator integration.  Do not attempt to connect a gas generator to 

the battery system.  If generator support is required, consult your installer regarding a separate manual transfer to your backup 
electrical panel. 

5  Maintenance 

 

The Evolve home energy storage system is a maintenance free product.   Regularly scheduled inspection of the airflow path for the 

active cooling fans on the bottom side of the PCS cabinet is all that is required.  This inspection should occur on an annual basis, 
or coincide with PV inspection. 
 

If the fan ventilation holes are obstructed with dust / debris, a soft-bristled brush can be used to wipe them clean.  For heavy soiling 
use a soft, dry brush. Do not use any solvents, scouring, or corrosive materials to clean the unit. Never remove or unplug 

connections or plugs during cleaning. 
 

 

Observed state 

Action 

Service button command 

All panel lights off 

Wake panel display 

Press and release 

Service light on 

Exit service mode 

Press and hold 5 seconds 

Summary of Contents for Evolve 0513

Page 1: ...Eguana Evolve Model Evolve 0513 DO 68025 Evolve Owner s Manual ...

Page 2: ...hock serious injury or death Operating the product in a way that it was not intended can also result in permanent damage to the product This manual applies to the following products Evolve 0513 Energy Storage System Warranty The Eguana Evolve includes a 10 year standard warranty with performance pro rating for the battery modules Please review the warranty statement included with your product IMPO...

Page 3: ...GENCY 1 1 3 ENVIRONMENTAL PROTECTION 2 2 INTRODUCTION 3 2 1 OVERVIEW 3 2 2 SYSTEM MONITORING ACCOUNT SETUP 4 3 OPERATION 4 3 1 LED DISPLAY INDICATORS 4 3 2 SERVICE BUTTON 5 4 BACKUP POWER OPERATION 5 5 MAINTENANCE 5 6 TROUBLESHOOTING 6 7 INSTALLER CHECKLIST 6 ...

Page 4: ... to the installed location In case of fire When safe use a fire extinguisher suitable for use including A B and C dry chemical fire extinguishers or carbon dioxide extinguishers Do not use type D extinguishers In case of flooding Stay out of water if any part of the system or wiring is submerged Do not attempt to operate batteries that have been submerged in water even after they have been dried I...

Page 5: ...trical panel Ensure proper electrical grounding in accordance with code requirements CAUTION Both AC and DC voltage sources are terminated inside this equipment Each circuit must be disconnected before servicing Risks of Damage The PCS is compatible with the LG Chem battery model EM048126P3S7 only Do not attempt to connect any other battery to the system Do not connect any other loads directly to ...

Page 6: ...ram below shows a typical layout of an AC coupled solar plus storage system Your system may be installed in a manner differently than shown above In addition in accordance with your local electrical code your installer may have included dedicated emergency disconnect switches for your battery and solar systems Consult your system installer regarding the application and installation setup of your s...

Page 7: ...s present operating conditions 3 1 LED Display Indicators The display panel provides indication of the following Battery status state of charge System operating mode out of Service Indicator To conserve energy the LEDs will turn off after 5 minutes from being activated They can be re activated by pressing the service button Indicator Status Display type Color Battery Status State of charge L R 5 L...

Page 8: ...er in the home will be interrupted for up to four seconds before backup power generation commences As a result of this interruption a desktop or portable UPS is recommended if continuous uninterrupted operation is desired for any sensitive electronic equipment In the event that there is not enough solar generation to maintain battery operation in an extended duration grid outage the battery system...

Page 9: ... connection is via wi fi reboot wireless router and make sure login user and password have not been changed since time of original installation Check power to the Evolve energy management system via the orange indicator light on the right side of the panel Note the energy management system may lose power after an extended grid outage where there is not enough solar generation to maintain battery s...

Reviews: