5
3.2 Service Button
The service button can be used to wake the LED display, and either put the system into or out of service mode, as well as cycle
through various operating modes.
IMPORTANT! In the event that the system has gone out of service, please consult your installer for guidance. Depending on the
nature of the service fault, your installer may advise you to reset the system on your own, or schedule a service visit.
4 Backup Power Operation
This system will provide backup power to dedicated electrical circuits within the home via a permanently wired electrical sub-panel,
referred to as the backup panel. The power source is limited in power rating and duration, both of which are dependent on the
nature of the loads connected to the system, and the available solar supply. This system is designed to reliably provide power to a
refridgerator, home lighting, home electronics, and small appliances.
IMPORTANT! Surge rated loads (compressor and motor type loads) may greatly reduce the power output capability of the battery
system, and cause premature overload conditions. Equipment of this type that is connected to the backup panel should be
inspected and tested regularly as per manufacturer suggested schedules. Do not attempt to add loads of this type to the backup
panel without consulting your installer. Permanent damage to the battery system and/or your equipment may occur if exposed to
chronic overloading cycles.
IMPORTANT! Portable extension cords connected to a backup circuit should be limited to 10 meters. Do not attempt to power
loads to outbuildings while in backup mode.
NOTE: While the battery system does provide grid quality backup power (pure sine wave) following a grid outage, the power in the
home will be interrupted for up to four seconds before backup power generation commences. As a result of this interruption, a
desktop or portable UPS is recommended if continuous, uninterrupted operation is desired for any sensitive electronic equipment.
In the event that there is not enough solar generation to maintain battery operation in an extended duration grid outage, the battery
system will automatically shutdown to a standby state with a minimum operating reserve, and attempt to restart at the beginning of
the next solar charge cycle. During the standby state, there will no longer be any backup power available. This cycle will repeat
until, a) the grid power returns, or b) the battery depletes to a hibernation state, where no backup power is available. In the event
that the battery reaches hibernation, the grid power must be available to restart the battery system.
IMPORTANT! This product does not support automatic gas generator integration. Do not attempt to connect a gas generator to
the battery system. If generator support is required, consult your installer regarding a separate manual transfer to your backup
electrical panel.
5 Maintenance
The Evolve home energy storage system is a maintenance free product. Regularly scheduled inspection of the airflow path for the
active cooling fans on the bottom side of the PCS cabinet is all that is required. This inspection should occur on an annual basis,
or coincide with PV inspection.
If the fan ventilation holes are obstructed with dust / debris, a soft-bristled brush can be used to wipe them clean. For heavy soiling
use a soft, dry brush. Do not use any solvents, scouring, or corrosive materials to clean the unit. Never remove or unplug
connections or plugs during cleaning.
Observed state
Action
Service button command
All panel lights off
Wake panel display
Press and release
Service light on
Exit service mode
Press and hold 5 seconds