Document ID: OMM-00148 Rev. B
47
4.3.9 Parameters Window
Click the Parameters button in the EFI Pro 24f Control window’s tool bar to open the Parameter
Settings window, including the
System Tab
,
Page Settings Tab
,
Offset Tab
,
Head Voltage Tab
,and
Head Temperatures Tab
..
System Tab
The Systems Tab contains the following items:
1.
Micro Drop Interval and drop times for the "misting" of print heads
during sleep mode. This is not required for UV inks, so Interval
and Drop Times can be set to zero.
2.
Ink System Control. Check White Ink Bottle Recirculation to acti-
vate a cycle of the W1 and W2 ink pumps. Recirculating white ink
reduces its viscosity, thus avoiding ink clogging on the system.
Clear the check box to deactivate recirculation system.
3.
Auto Clean: sets the number of passes until printer operation
pauses for automatic purge and sweep, then resumes printing.
This number only resets when the printer is powered down.
4.
Resets Cleaner Case (Vacuum Canister)
5.
If checked, printer advances media through blank/white space.
See
6.7 Skip Blank Space During Prints
.
6.
Sets Sleep Mode Timer
7.
Mists the print heads before printing. Should be set to 1.
8.
Sets speed of media advancement when “Skip at blank space” is
checked. Should be set to 40000 Pulse/Second.
9.
OK
to save and exit.
Cancel
to exit without saving.
Figure 4-19: Parameters
Button on Tool Bar
Figure 4-20: Parameters System Tab