5.3.4.2

 

 POWER CABLES CONNECTION 

 

 

EVERY  OPERATION  ON  THE  EFAPOWER  EV-HC  MUST  BE  EXECUTED  BY  QUALIFIED  PERSONNEL  AND 
PROPERLY AUTHORIZED. DO NOT OPERATE IN CASE OF WATER PRESENT OR HUMIDITY. 
BY  OPENING  THE  EFAPOWER  EV-HC 

STATION’S

  COVERS  YOU  RUN  RISK  OF  EXPOSURE  TO  DANGEROUS 

VOLTAGES! 

After unpacking and physically installing, the authorized technician must start installing the input cables.  

 
Before connecting the EFAPOWER EV-HC must be assured:

 

 

The  Grid  Voltage  level  and  frequency

 

match

  the 

specifications

  on  the  EFAPOWER  EV-HC 

characteristics label 

 

The 

Ground

 

connection

 is connected in 

accordance

 with the 

harmonized

 

standards

 or 

local

 

regulation

 

 

The 

upstream

 

protection

 is 

provided

 for the Unit 

To ensure protection to technicians during installation of the EFAPOWER EV-HC, please verify the connections 

are done according to the following conditions:

 

 

There is 

no

 

input

 

Voltage

 (not connected to the Grid); 

 

No 

connection

 to 

Loads

 from the 

EFAPOWER

 

EV-HC

 

 

The 

EFAPOWER

 

EV-HC

 is 

OFF

The input AC connections are done on the Charging Station as represented in Figure 12 through the grommet 
mentioned below: 

 

For 

3,7kW/ 7,4kW

 

- 1Ph+N+PE, 50/60Hz, and shall come 

through

 the 

right

 

grommet

 

 

For 

11kW/ 22kW

 

- 3Ph+N+PE, 50/60Hz, and shall come 

through

 the 

middle

 

grommet

 

Cable section of each line, depending on the power rate of EV-HC, can be consulted in Table 3 on page 9. 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Figure 12 

 Home Charger (front view) - Input Terminals

 

 

X1 

 

HC 11

 or

 HC 22 

 

 

X1 

 

HC 3

 or

 HC 7 

 

Summary of Contents for EFAPOWER EV HC G3

Page 1: ...EFAPOWER EV HC G3 HOME CHARGING STATION Installation and User Manual...

Page 2: ...rademarks or registered service marks of their respective owners Symbols Index The following symbols are used in this manual to prevent accidents which may occur as a result of incorrect use of the ch...

Page 3: ...9 5 2 2 Surface Preparation 10 5 2 3 Resources for Installation 10 5 2 4 Site Verification and Inspection 10 5 3 HANDLING AND PLACING 11 5 3 1 Packaging 11 5 3 2 Visual Inspection 11 5 3 3 Handling 11...

Page 4: ...constitute a contractual obligation No part of this document may be photocopied reproduced or translated to other language without the written consent from EFACEC In case of any doubt regarding a sub...

Page 5: ...7kVA 7 4kVA 11kVA and 22kVA EFAPOWER EV HC station is user friendly and safe Different models are available with power plug or socket When equipped with a socket the power cord plug is coupled into it...

Page 6: ...ing with GB T20234 2 CE Units Type 2 according to EN 62196 2 GB Units Mode 3 according with GB T20234 2 EV Connection to EVSE CE units EN 61851 1 and IEC 61851 1 Case B and IEC 61851 1 Case C GB units...

Page 7: ...61851 22 Electric vehicle conductive charging system Part 22 AC Electric Vehicle Charging Station 10 EN IEC 61000 6 1 Electromagnetic compatibility EMC Part 6 1 Generic standards Immunity for residen...

Page 8: ...s Figure 3 EFAPOWEREV HC 3 7Parts RFID if applicable Output connection 3 7kVA 7 4kVA Output signaling Meter if applicable RCD and CB if applicable left side front side EV XX G3 YY 0F 00 G KK ZZP ZZ Me...

Page 9: ...plicable codes or safety standards This document describes the most commonly used installation and mounting scenarios If situations arise in which it is not possible to perform an installation followi...

Page 10: ...t ensure that the Unit can operate reliably while remaining within the range of its operating specifications 5 1 1 LOCAL CONDITIONS EFAPOWER EV HC Station has a protection degree of IP54 This Unit is...

Page 11: ...r very low temperatures it s recommended to provide additional protection either inside a building or a shelter or providing a roof protection for the Unit See example in Figure 6 Figure 6 EFAPOWEREV...

Page 12: ...suppressor please refer Figure 7 and Figure 8 Depending on the output of the Unit we can have several scenarios for the circuit breaker to be installed in the distribution board for each Unit The appr...

Page 13: ...5mm2 4mm2 32 A 4mm2 4mm2 Tools Screwdriver for wall mount Crimping tool for power and earth cables Torque screwdriver with flat blade for input terminal blocks 5 2 4 SITE VERIFICATION AND INSPECTION C...

Page 14: ...CKAGING EFAPOWER EV HC Station is shipped in a personalized package 493x400x187mm please refer to Figure 9 The Unit dimension is in Technical characteristics 2 1 5 3 2 VISUAL INSPECTION Check if the e...

Page 15: ...t be hanging on the wires a Unplug the earth cable on it faston terminal b Unplug the flat cable on the board X14 c Unplug the card reader cable on the board X6 if applicable 3 Fix the Unit to the wal...

Page 16: ...rs 5 3 4 2 and 5 3 4 3 EV HC11 EV HC22 Left grommet Charging Cable if applicable Middle grommet Input power cables refer chapters 5 3 4 2 and 5 3 4 3 Right grommet Communications refer chapter 5 3 4 4...

Page 17: ...nected in accordance with the harmonized standards or local regulation The upstream protection is provided for the Unit To ensure protection to technicians during installation of the EFAPOWER EV HC pl...

Page 18: ...Table 3 on page 9 5 3 4 4 COMMUNICATIONS IF APPLICABLE When applicable the communications on the EV HC shall be done through X2 double terminal marked with a red circle represented in both EV HC boxes...

Page 19: ...e EV HC If it s not suitable the USB RS485 converter connected directly to the EV HC due to distance constraints alternative pre installation it s allowed Figure 15 A shielded communication cable of a...

Page 20: ...n excel file ant therefore reports of charge associated to a specific RFID card can be generated ATTENTION There is a Maximum limit of the number of the chargers that can be connected this way 127 cha...

Page 21: ...minal of the EV HC the respective RS 485 cables of the satellites network Is possible to have a network up to 25 satellite units In this solution the RFID card reader is only located on the Central Un...

Page 22: ...ST NOT BE STARTED OR PUT INTO USE WITHOUT HAVING BEEN COMMISSIONED BY A FULLY TRAINED AND AUTHORIZED PERSON ALL SERVICING MUST BE PERFORMED ONLY BY QUALIFIED PERSONNEL DO NOT ATTEMPT TO SERVICE THE EF...

Page 23: ...lever There is a test button for operation and differential protection test After connecting the charging station for the first time wait a few seconds and the EV HC Station should be ready to use AT...

Page 24: ...pter 7 1 OUTPUT CONNECTOR EFAPOWER EV HC is prepared to charge electric vehicles according to the mentioned charging systems 7 1 1 TYPE 1 CONNECTOR Mode 3 7 1 2 TYPE 2 CONNECTOR Mode 3 7 1 3 TYPE GB C...

Page 25: ...QUENCES FOR EV HC WITHOUT AUTHENTICATION The green light Ready indicates the EV HC is ready to be connected to a vehicle In the following figure is represented the operation sequence to start charging...

Page 26: ...lowing figure is represented the stop charging sequence At this stage the station is ready to charge another vehicle NOTE If the user left the station charging and when returned light is blinking blue...

Page 27: ...ith authentication or by disconnecting the cable from the car In the following figure are the sequences for each method NOTE If the user left the station charging and when returned light is blinking b...

Page 28: ...damages caused after the warranty period but will gladly provide its customers with any technical consulting 8 1 PREVENTIVE MAINTENANCE This equipment must be kept in perfect condition to guarantee a...

Page 29: ...D s EV HC without authentication The Homecharger is ready but the charging process didn t start The connector is not properly plugged into the vehicle Verify the correct connection to the vehicle The...

Page 30: ...E F A P O W E R E V H C I N S T A L L A T I O N A N D U S E R M A N U A L 27 28 This Page Intentionally Left Blank...

Page 31: ...E F A P O W E R E V H C I N S T A L L A T I O N A N D U S E R M A N U A L 28 28 This Page Intentionally Left Blank...

Page 32: ...R EV HC G3 INSTALLATION AND USER MANUAL V 06 00 Rua Eng Frederico Ulrich Apartado 3078 4471 907 MOREIRA MAIA PORTUGAL Tel 351 229403241 Fax 351 229403209 serviceEEM efacec com www electricmobility efa...

Reviews: