Technical data
Note:
Pumping speeds quoted are without an inlet screen
Table 5 - nEXT 400 pumps technical data
Parameter
nEXT400D
ISO160
nEXT400D
CF160
nEXT400T
ISO160
nEXT400T
CF160
Mass
6.5 kg
9.5 kg
6.8 kg
9.8 kg
Inlet flange
DN160ISO-K
DN160CF
DN160ISO-K
DN160CF
Outlet flange
DN25NW
DN25NW
DN25NW
DN25NW
Vent port
⅛
inch BSPP
⅛
inch BSPP
⅛
inch BSPP
⅛
inch BSPP
Purge port
⅛
inch BSPP
⅛
inch BSPP
⅛
inch BSPP
⅛
inch BSPP
Interstage port
DN25NW
DN25NW
DN25NW
DN25NW
Booster port
DN25NW
DN25NW
DN25NW
DN25NW
Inlet pumping speed
N
2
He
H
2
400 l/s
390 l/s
325 l/s
400 l/s
390 l/s
325 l/s
400 l/s
390 l/s
325 l/s
400 l/s
390 l/s
325 l/s
Inlet compression ratio
N
2
He
H
2
>1 x 10
11
1 x 10
8
5 x 10
5
>1 x 10
11
1 x 10
8
5 x 10
5
>1 x 10
11
>1 x 10
8
1 x 10
6
>1 x 10
11
>1 x 10
8
1 x 10
6
Interstage pumping speed
N
2
He
H
2
13 l/s
13 l/s
11 l/s
13 l/s
13 l/s
11 l/s
13 l/s
13 l/s
11 l/s
13 l/s
13 l/s
11 l/s
Peak booster
Pumping speed (nitrogen)
RV12 backing pump
XDS10 backing pump
-
-
26 m
3
h
-1
24 m
3
h
-1
26 m
3
h
-1
24 m
3
h
-1
Ultimate pressure
*
*
Ultimate pressure 48 hours after bakeout for CF version and without bakeout for ISO version with 2-stage
rotary vane backing pump.
<1 x 10
-8
mbar
<1 x 10
-10
mbar
<1 x 10
-8
mbar
<2 x 10
-10
mbar