Technical Data
Note:
Only slm gas flow values are given in the table, because only slm values can be entered in the Pump Display
Terminal. To convert slm values to PA ls
-1
, multiply by (1.013/60) x 10
5
.
Table 8 - Electrics module default setpoints
Parameter
Unit
Default setpoint values
Low alarm Low warning High warning
High alarm
FDP pump temperature
°
C
ADJ
ADJ
75
85
FDP motor cooling-water return
temperature
°
C
ADJ
ADJ
55
ADJ
HMB1800 pump temperature
°
C
ADJ
ADJ
165
170
Exhaust gas temperature
°
C
ADJ
ADJ
220
ADJ
Table 9 - Gas module default setpoints: High gas configuration
Parameter
Unit
Default Setpoints
Low Alarm
Low Warning
High Warning
High Alarm
Dilution purge off
slm
24
28.5
ADJ
ADJ
Dilution purge on
slm
30
35
ADJ
ADJ
Inlet purge on
slm
30
35
ADJ
ADJ
Exhaust pressure
psig
ADJ
ADJ
4.0
7.0
Shaft seals pressure
psig
ADJ
ADJ
12.5
ADJ