EDT, Inc.
2019 April 29
31
VisionLink F-series
Appendix B: Diagrams
–
Boards and Cabling
Additional External Inputs
Via Berg or Optional Lemo Connector
VisionLink frame grabbers offer two connectors that can be used for external control (triggers and other inputs, such as
IRIG-B for timestamping): one Berg, and one optional seven-pin Lemo. Pin assignments are shown below.
BERG CONNECTOR [STANDARD]
Pin
VisionLink F1
VisionLink F4
1
Trigger 0+
Trigger 0+
2
Trigger 0-
Trigger 0-
3
Trigger 1+
Trigger 1+
4
Trigger 1-
Trigger 1-
5
Reserved or (optional) IRIG-B
IRIG-B
6
3.3V
3.3V
7
Reserved
Reserved
8
Reserved
Reserved
9
Reserved
Reserved
10
Ground
Ground
LEMO CONNECTOR [OPTIONAL]
Pin
VisionLink F1
VisionLink F4
1
Trigger 1+
Trigger 1+
2
3.3V
3.3V
3
Trigger 0+
Trigger 0+
4
Trigger 0-
Trigger 0-
5
IRIG-B
IRIG-B
6
Trigger 1-
Trigger 1-
7
Ground
Ground
Via Optional Cable Assembly
An optional EDT-built cable assembly is available for triggering, timestamping, or both; below are the pin assignments
(see also
EDT p/n 016-13840 (June 2010)
[color]
Lemo D9 Function
BNC
BNC Label
:
green
1
2 trigger 1+
center conductor
TRIG 1
red
2
9 reserved
–
–
orange
3
7 trigger 0+
center conductor
TRIG 0
brown
4
8 trigger 0-
shield
TRIG 0
white
5
4 IRIG IN
center conductor
IRIGB
blue
6
3 trigger 1-
shield
TRIG 1
black
7
5 ground
shield
IRIGB
For length, Lemo to D9 = 1 ft.; three BNCs out to D9 = each 6 in. or less.
1
6
2
7
5
3
4
2
4
6
8
10
1
3
5
7
9