9
Parameter description
And
Default values on far right(..)
Language
Select language-------------------------------------------------------------- (English)
High Tension
Tension in electromagnet
at time of high tension-------------------------- 220VDC to 300VDC (240VDC)
T-High Tension
Time in which High Tension will be active------------------------ 5 to 15 s (6s)
Transport Tension
Tension in electromagnet
at time of Transport tension------------------- 180VDC to 240VDC (220VDC)
Time out delay
Maximum charge time ------------------------- 0 to 10 minute 0=infinity
(5 minute)
Generator amperage (Electro10%)
Alarm amperage---------------------- 15 to 200 amps (100 amps) *
Field Voltage
Field tension--------------------------------------------------- 120v to 300v (250v)
Droping amps
Amps of first droping --------------------------------------- 0 to 20 amps (0) *
Ratio 1’ droping
Power of first droping sequence --------------- 1 to 10/10 (5)
* This parameter will chage with autoajustement
INPUT/OUTPUT (CODE 72)
TB SW- MODE
-TWIN + BOOST First short puls made load all other short pulse
restart hight volt time and a long pulse made a droping cycle.
-TWIN - BOOST First short puls made load and a long pulse made a
droping cycle.
-PULS First short puls made load and a next pulse made a
droping cycle.
.
DEFAULT IS TWIN + BOOST