6
Working with the Controller
Manual Drop with one button mode
1-
Press briefly on the command button for less than 0.5 seconds and the controller will
activate the electromagnet.
2-
Each time that you briefly apply the command button, the controller will reactivate the High
Tension for a time determined by the parameter ``T-High Tension’’.
3-
To drop the metal, hold the command button again for more than 0.5 seconds.
4-
Manual Drop with two button mode
Press on the second button it will be connected to (TB IN) . It was be programmed for droping
(NO or NC) with code 72. (NO) is more safe. This parameter will deactivates the single button mode.
Auto Drop one button mode
Hold the command button for more than 0.5 seconds; as soon as the button is released the
metal will drop.
Sorting
Press on the command button for more than 0.5 seconds then drop momentarily for more than
0.5 seconds. This coordination will made a quick release and grasp of the materials.
You can repeat this step with a longer release and as often as you want without overheating the
controller.