Extinguish Mode

This option when programmed by your installer will cause the indicators on your
console to automatically extinguish if the console is not used for a period of sixty
seconds. At any time the indicators can be brought back to an illuminated state by
pressing a button, an alarm condition or when the system is in entry time. The indicators
will not illuminate if a silent alarm is triggered.

NOTE:

This option can only be programmed by your installer

.

Console Operations

Introduction

The following pages will describe how to use and interpret the many console functions
that are available on the 

Solution-8

.

Most functions are performed using the master code.

Before attempting to enter any of the master code functions ensure that the system is in
the disarmed state and that there are no alarm memory indicators flashing. If this is not
the case the following will be required.

If  the zone indicators are flashing fast at three pulses per second, key in your master
code followed by the AWAY button.

If the panel becomes armed, (ie. the AWAY indicator is illuminated) key in your code
followed by the AWAY button again. This will place the system back into the disarmed
state.

If the system is not disarmed, (ie. the AWAY or STAY indicators are illuminated) key
in your code followed by the AWAY button.

The factory default master code is 

2580. 

This code can be changed at any time therefore

if your system master code differs from the default, please substitute your existing
master code in the following examples.

This code allows you to change any users code and even the master code itself. It is also
the only code that allows the execution of special functions as detailed later in this
manual.

Codes can be up to six digits in length. This is dependent on the configuration set up by
you installer.

Provided 

for 

Download 

by 

www.bendigosecurity.com.au

Summary of Contents for Solution-8

Page 1: ...8 Issue 3c September 1994 Electronics Design Manufacturing 1994 1995 All rights reserv Control Panel Copyright MA 800 O P r o v i d e d f o r D o w n l o a d b y w w w b e n d i g o s e c u r i t y c...

Page 2: ...control panel please refer to the following table and substitute the correct button and indicator names to suit your particular console CP5 CP3 CP4 STAY button HOME button STAY Indicator HOME Indicato...

Page 3: ...ING IN AWAY MODE 11 ARMING IN STAY MODE 11 DISARMING 12 ISOLATING ZONES 12 DAY ALARM 13 ALARM MEMORY RECALL 14 WALK TEST MODE 15 CONSOLE DURESS ALARM 15 CONSOLE PANIC ALARM 16 CONSOLE TAMPER 16 AUXILI...

Page 4: ...s condition As batteries do not last forever this feature will warn you of poor battery condition before an alarm occurs Day alarm warning allows you to monitor the opening of a front door in a shop o...

Page 5: ...ble devices such as sirens and trigger strobe and the dialler The dialler will then transmit all relevant alarm information via the telephone line alerting the respective persons of the current state...

Page 6: ...dications that will be seen Zone Indicator Indication Definition Off Zone Sealed On Zone Unsealed Flashing Fast Zone Alarm Condition Flashing Slow Zone Isolated Away Indicator The AWAY indicator is us...

Page 7: ...ion Indication Definition Off System Normal On System Failure or displaying the digit 9 during programming Audible Indications In general the audible indicators given out by the console are as follows...

Page 8: ...rm memory indicators flashing If this is not the case the following will be required If the zone indicators are flashing fast at three pulses per second key in your master code followed by the AWAY bu...

Page 9: ...ses per second to indicate a successful entry Now key in the user number that you wish to alter followed by AWAY button You will hear two beeps and the corresponding zone indicator will illuminate Use...

Page 10: ...ING mode key in the current MASTER CODE followed by the number 1 then AWAY You will hear three beeps and the AWAY indicator will flash fast at three pulses per second to indicate a successful entry No...

Page 11: ...y handy It automatically disables the interior detection zones allowing for movement within the protected area while at the same time arming the perimeter zones To activate the system in STAY mode key...

Page 12: ...de key in the zone number that was incorrectly entered This zone is now no longer isolated and the zone indicator will stop flashing as the zone returns to normal When the correct zones are isolated p...

Page 13: ...modes As there may be a need from time to time to disable this feature you have the ability to do so via the console Simply turn the day alarm on and of as is required To turn Day Alarm on key in you...

Page 14: ...will be played back via the zone indicators on the console in reverse chronological order Example If the events were as follows 1 System armed 2 Alarm zone 3 3 Alarm zone 4 4 System disarmed Then the...

Page 15: ...le beep and the system console will give a long beep indicating that the zone is functioning correctly To turn Walk Test off press the AWAY button two beeps will be heard and the system will return to...

Page 16: ...Console Tamper An alarm can be triggered if the console is being tampered with Such an event might be someone repeatedly entering the incorrect code The number of incorrect attempts that are required...

Page 17: ...e already been programmed the panel will begin to display the numbers via the system console using the zone indicators The first number will be displayed for two seconds and then a beep will be heard...

Page 18: ...r 3 successful calls If busy tone is not detected then the panel will assume that the phone has been answered and will begin sending its transmission The transmission consists of a siren tone followed...

Page 19: ...er reporting formats have been introduced so that alarm and system information can be transferred to a pocket pager allowing you to receive information from your alarm system at any time Two transmiss...

Page 20: ...lient 678 with an alarm on zone four while the system is armed and all other events are normal 678 00010000 9000 1 2 3 4 5 6 7 8 Zone Normal 0 Alarm 1 Manually Isolated 2 Zone Status Client ID Number...

Page 21: ...re more information is needs to be transferred then multiple calls will occur Example This example shows that the transmission has come from client number 678 and that 2 new events have occurred As th...

Page 22: ...g beep will be heard to indicate that the system has become armed Now hang up the telephone and the system will remain armed If the Solution 8 control panel does not answer the call this means that th...

Page 23: ...ct your system to a remote control radio receiver This equipment when fitted will enable you to control the general operation of your system from a portable hand held transmitter It can even be used f...

Page 24: ...ined siren unit complete with strobe light and back up battery Offers a higher level of security for the alarm system Entry Time Entry Delay The time allowed for entering the ARMED premises to DISARM...

Page 25: ...detector is on stand by waiting for an intrusion Silent alarm When programming the Solution 8 it is possible to program an individual zone for SILENT ALARM this means that when the zone is violated th...

Page 26: ...operations of Electronics Design Manufacturing include design development and manufacturing of electronic equipment Electronics Design Manufacturing recognises that it is the responsibility of supplie...

Page 27: ...ne Number __________________________________________________ Installation Date _________________________________________________ Warranty Expires ________________________________________________ Descr...

Page 28: ...P r o v i d e d f o r D o w n l o a d b y w w w b e n d i g o s e c u r i t y c o m a u...

Reviews: