ELECTRICAL CHARACTERISTICS
Power supply
/- 10% 50 Hz
Average power consumption
120 W
Power consumption during ignition
400 W
Protection on electronic circuit board
T2A, 250 Vac, 5x20 Fuse
TECHNICAL DATA FOR SIZING THE FLUE
which must, in any case, comply with the guidelines of
this sheet and the installation rules for each product
Nominal power
Reduced power
Thermal power output
13
3,9
kW
Temperature of fumes on exit from the discharge pipe
155
67
°C
Minimum draught
0 - 5
Pa
Fume fl ow capacity
10,6
3,6
g/s
THERMO TECHNICAL CHARACTERISTICS
according to EN 14785
(for other values, see DoP on page 40)
Nominal power
Reduced power
Thermal power output
13
3,9
kW
Thermal power transferred to the water without fan
10
3
kW
Thermal power transferred to the environment
3
0,9
kW
Yield / Effi ciency
91,6
97,6
%
Emissions CO 13% O
2
0,010
0,025
%
Fume temperature
129
56
°C
Fuel consumption
3
0,8
kg/h
Draught
12 - 5
10 - 3
Pa
Hopper capacity
30
kg
Water content
12
Litres
Maximum operating pressure of the water
1,5
bar
Maximum operating temperature of the water
90
°C
Autonomy
9
34
hours
Heatable volume *
340
m
3
Smoke outlet pipe diameter (male)
80
mm
Air intake pipe diameter (male)
40
mm
Weight including packaging (ceramic/steel)
250 / 230
kg
N.B.
1) keep in mind that external devices can cause interference to the operation of the circuit board.
2) warning: activity on live components, maintenance and/or checks must be carried out by qualifi ed personnel.
(before carrying out any maintenance, disconnect the appliance from the mains electricity)
3) In case of problems with the electrical grid, consult an electrician to evaluate the installation of a sine-wave UPS of at
least 800 Va. Power variations greater than 10% can cause problems for the product.
The above data are indicative and are those resulting during certifi cation on the part of the notifi ed body.
EDILKAMIN s.p.a. reserves the right to change the products at its discretion without notice.
*
The heatable room dimensions are calculated on the basis of home insulation in compliance with Italian law 10/91, and subse-
quent changes together with an expected heat output of 33 Kcal/m³ per hour.
Summary of Contents for MITO IDRO
Page 10: ... 10 ITALIANO INFORMAZIONI GENERALI ...
Page 39: ... 39 ENGLISH GENERAL INFORMATION ...
Page 68: ... 68 FRANÇAIS INFORMATIONS GÉNÉRALES ...
Page 126: ... 126 126 DEUTSCH ALLGEMEINE INFORMATIONEN ...
Page 184: ... 184 DANSK 184 GENERELLE OPLYSNINGER ...
Page 263: ......
Page 293: ......
Page 352: ... 352 cod 941204 12 16 H w w w e d i l k a m i n c o m ...