- 89
-
ENGLISH
POSSIBLE TROUBLESHOOTING
INDICATION OF POSSIBLE CAUSES OF MALFUNCTION INSTRUCTIONS AND SOLUTIONS (TSC)
SIGNALLING
PROBLEM
ACTIONS
Er12
Failed switch on block
(activates if within a maximum
time of 20 minutes the
fl
ame does not appear
or the smoke temperature
of 60° C is not reached).
Distinguish between the following two cas-
es:
NO fl ame appeared
Check:
• positioning and cleaning of the crucible
(User)
• switch on resistance functionality (TSC)
• Try to ignite with a
fi
relighter.
(User)
The fl ame has appeared, but after switch
on the writing Er03 appears.
Check:
• thermocouple functioning (TSC).
• start-up temperature set in
parameters (TSC)
Er15
No mains block
(not a defect of the boiler).
No electrical power for more
than 50 minutes.
Check the electrical connection and drops in
voltage (User)
Er23
Boiler or buffer temperature
probes error
Incorrect reading of the probes.
Check the probes and their connections
(TSC).
Link Error
Communication error
between the electronic board
and the display
Cut power from the boiler, wait a few
minutes and then power again (User)