- 70
-
ENGLISH
COMBUSTION MANAGEMENT MENU
Menu to change the system combustion parameters. It is composed of some sub-menus.
POWER
Menu consisting of setting the system combustion power. It is possible to choose between auto-
matic and manual.
FUEL RECIPE
Menu that allows you to choose the type of fuel to use.
ATTENTION: DO NOT MIX FUELS WITH ONE ANOTHER
In the event of fuel change, you need to fi rstly completely empty the tank, change the reci-
pe as per the table and then fi ll the tank with the new fuel.
N.B.: The recipes refer to standard fuel. Adapt the recipe to your fuel by calibrating the auger and
the fan.
AUGER CALIBRATION
Menu that allows variation in the working time of the auger You have available 10 adjustment
steps, 5 increase steps and 5 decrease steps, value 0 corresponds to the calibration value set in
the factory.
An adjustment step corresponds to 5% of the value set in the factory. Calibration affects the recipe
used and all the power values.
FAN CALIBRATION
Menu that allows you to change the speed of the smoke fans You have available 10 adjustment
steps, 5 increase steps and 5 decrease steps, value 0 corresponds to the calibration value set in
the factory.
An adjustment step corresponds to 5% of the value set in the factory. Calibration affects the recipe
used and all the power values.
INSTRUCTIONS FOR USE
Combustion
Description
1 – 5 Power
Power adjusted in manual mode 1 to 5
Auto
Power regulated in automatic mode by system
Recipe
Fuel
Recipe no. 1
Pellets
Recipe no. 2
Olive waste
Recipe no. 3
Hazelnut shells
Heating Management
Chrono
Loading
Service Reset
Pellet Power
Pellet Recipe
Auger Calibration
Combustion Management
Fan Calibration