- 62
-
ENGLISH
INSTALLATION
[metres c.a.]
[l/h]
0
100
200
300
400
500
600
0
200
400
600
800
1000
1200
1400
1600
1800
Flow Rate [dm3/h] prevalenza pompa
Flow Rate [dm3/h] perdite di carico
Flow Rate [dm3/h] prevalenza residua
perdita valvola
prevalenza res con valvola
ANTI-CONDENSATE KIT OPTIONAL
For correct operation, you need to guarantee a return temperature of at least 55° in the boiler, to
avoid condensate formation in the smoke tubes. For example, you are advised to use an anti-con-
densate mixer.
A return temperature in the boiler under 55° C causes the structural warranty to EXPIRE.
Edilkamin cannot be held liable for any damages due to non-compliance with the minimum return
temperature. The diagram includes use of accessories available on the EDILKAMIN pricelist.
ANTI-CONDENSATE VALVE CHARACTERITIC BEND
pump pressure head
load loss
residual pressure head
valve loss
residual pressure head with valve
BOILER
OUTPUT
BUFFER
OUTPUT
BUFFER
RETURN
BOILER
RETURN
VALVE
ANTI-CONDENSATE
6
5
4
3
2
1