SECTION 2:
SPECIFICATIONS
2-10
3100-P PORTABLE SUB-BOTTOM
0004802_REV_F
2.2.1
35-Meter Kevlar Reinforced Tow Cable Specifications
The general specifications for the 35-Meter Kevlar Reinforced Tow Cable are shown in
SPECIFICATION
VALUE
Twisted-shielded wire pairs:
(1) # 16 AWG
(2) # 20 AWG
Breaking strength:
1,500 kg (3,300 lb) minimum
Working strength:
300 kg (660 lb)
Weight in air:
94 kg/100 m (207 lb/1000 ft)
Voltage rating:
600 volts
Bending radius:
25 cm (10 in.) minimum
Length:
35 m (115 ft) standard
Table 2-6: 35-Meter Kevlar Reinforced Tow Cable Specifications