6-11
6.3.8
Tow Cables
Historically, most system problems occur in the tow cable and their connectors. Before proceeding, verify
cable continuity from the shipboard end of the cable to the towfish. The presence of a shorted or open
wire in a tow cable can be determined by using a multi-meter. An open or shorted wire can be located
using the techniques described in the following subsections.
6.3.8.1
Shorted Wire
The following procedure may be used to approximate the distance to a single short or a point of high
leakage between a conductor pair or from a conductor to a shield.
Disconnect both cable ends.
1.
Short the two connector pins (or wires if un-terminated) of the shorted pair at both ends and
measure the total resistance between the ends.
R1+R2 =_______________
2.
Remove the shorts.
3.
Measure the resistance between a shorted pair on one end with an ohmmeter on the Rx1 scale.
R1+Rs =_______________
4.
Measure the resistance from the other end.
R2+Rs =_______________
5.
Add the measurements of 4) and 5) above, subtract the measurement of 2), and divide the result
by 2.
Rs =_________________
6.
Subtract the value of 6) from the measured values of 4) and 5).
R1 =_________________
R2 =_________________
7.
The distance to the short from end #1 is the ratio of (R1/R1+R2) times the total cable length.
Recheck from end #2 which is (R2/R1+R2) times the cable length.
6.3.8.2
Open Wire
An open wire in a cable is much more difficult to locate than a short circuit; therefore, a capacitance bridge
is recommended. Measuring the capacitance from the open wire to the shield on both ends allows two
different capacitance readings to be recorded. This represents a direct ratio related to cable length and
distance of break from each end. Before cutting the cable, double-check the same ratio of capacitance
Summary of Contents for 2000-TVD
Page 28: ......
Page 36: ...Figure 2 1 Overall Towfish ICD Diagram...
Page 37: ...Figure 2 2 Fiberglass Shell of Towfish...
Page 38: ...Figure 2 3 Tow Bridle Drawing 1...
Page 39: ...Figure 2 4 Tow Bridle Drawing 2...
Page 40: ...Figure 2 5 Towfish Assembly Drawing 2...
Page 41: ...Figure 2 6 Towfish Assembly Drawing 3...
Page 42: ...Figure 2 7 Towfish Assembly Drawing 4...
Page 44: ...Figure 2 9 300 Meter Tow Cable Specification Drawing...
Page 45: ...Figure 2 10 100 Meter Tow Cable Specification Drawing...
Page 46: ...Figure 2 11 15M Test Cable...
Page 47: ...Figure 2 12 Deck Cable...
Page 48: ...Figure 2 13 Armored Tow Cable with PMI Grip...
Page 53: ...Figure 3 1 Rack Mount Topside Front Panel...
Page 54: ......
Page 55: ...Figure 3 2 Rack Mount Topside Back Panel...
Page 68: ...Figure 4 1 Topside Computer Internal Components...
Page 71: ...Figure 4 3 STARMUX III Internal Components...
Page 73: ...Figure 4 5 STARMUX III Wiring Diagram...
Page 77: ...Figure 4 6 Towfish Electronics Chassis...
Page 78: ...Figure 4 7 2000 TVD Towfish Block Diagram...
Page 86: ...5 8 5 0 MAINTENANCE 2000 TVD COMBINED SONAR 0017424_REV_B Figure 5 9 Tera Term Splash Screen...
Page 110: ......