Versatrax 150™
Document: UMDW014058.docm
Revision: A03
Created by: KW
Date: 10 Oct 2019
3075415-A03
Source Location: C:\ePDM\ISLEng\products\dw-versatrax150mkii\manuals\UMDW014058.docm
Page 21 of 57
User Ma
nual
Powered Camera Raise
Note:
When the powered camera raise is installed, the minimum pipe size is increased to 350 mm (14 in)
to allow room for the mechanism.
The camera raise needs to be zeroed before each use. Click the calibrate button on the ICON
™
interface after system startup. The mechanism will lower itself to its lowest position, detected through a
magnetic switch. Note that the operator can control the motorized camera raise before calibrating after
system startup however the operator will not have any position feedback and it may be possible to
hyperextend the mechanism.
Note:
The Powered Camera Raise will
not
position feedback until it is calibrated
using ICON (Inuktun Controller Software).
Warning:
Keep hands clear of the camera raise when in operation as it presents
a potential pinching hazard.
Note:
Always make sure there are no obstructions to the camera’s movement
before operating the camera raise.
When packing the Versatrax 150™ into the optional Pelican shipping case with the powered camera raise
installed, make sure to adjust the height of the camera to its shipping height before powering down the
system. For packing, the tracks should be set FLAT, and the height of the camera should be between
115
– 130 mm (4.5 – 5 in) measured from the floor to the support bar underneath the camera.