Boiler Ignition
Supply unit with electricity.
Boiler ignition
)RUVHFRQGVGLVSOD\ZLZKLFKLGHQWL¿HVWKH
air venting cycle for the heating system.
'XULQJWKH¿UVWVHFRQGVWKHGLVSOD\ZLOOVKRZWKH
software release of the card also.
Open the gas valve before the boiler.
When FH vanishes, boiler is ready to automatically work
whenever hot tap water is drawn or room thermostat
requests heating.
7XUQLQJWKHERLOHURII
Press the button below (see item 7 on the control panel
display) for 5 seconds.
When the boiler is turned off, the electronic board is still
powered.
Domestic hot water and heating operation are disabled. The
antifreeze system remains activated.
To re-light the boiler, press the button (see item 7 on the
control panel display) again for 5 seconds.
Boiler will be immediately ready to operate whenever
domestic hot water is drawn or room thermostat demand.
6XPPHU:LQWHU6ZLWFKRYHU
Press the button for 2 seconds.
Display will activate Summer symbol (see item 10 on the
control panel display). Boiler will deliver tap water only.
Antifreeze system stays on.
To turn off Summer mode, press button again for 2
seconds.
Heating temperature setting
Use heating buttons (see items 3 and 4 on the control
panel display) to change the temperature from minimum of
86°F (30C) to a maximum of 185°F (85C); it is advisable to
not operate boiler below 113°F (45C).
'RPHVWLFKRWZDWHUWHPSHUDWXUHDGMXVWPHQW
Operate DHW buttons (see items 1 and 2 on the control
panel display) to vary the temperature from a minimum of
50°F (40C) to a maximum of 149°F (55C)
10 - OPERATING INSTRUCTIONS
28
EN
28
EN
Summary of Contents for CCB-150
Page 6: ...Figure 2 Component Listing 6 3 GENERAL VIEW AND MAIN COMPONENTS EN 6 EN...
Page 39: ...KEY 3DUW 1XPEHU Description 4W A01 FE3980B990 CASING CTR 1 39 REPAIR PARTS LIST EN 39 EN...
Page 41: ...41 REPAIR PARTS LIST EN 41 EN...
Page 43: ...43 REPAIR PARTS LIST EN 43 EN...
Page 45: ...45 NOTES EN 45 EN...
Page 46: ...46 NOTES EN 46 EN...
Page 51: ...Figure 2 Liste des l ments 51 FR 3 VUE D ENSEMBLE ET PRINCIPAUX L MENTS...
Page 84: ...CODE R f Description A01 FE3980B990 ENVELOPPE CTR 84 FR LISTE DES PI CES D TACH ES...
Page 86: ...86 FR LISTE DES PI CES D TACH ES...
Page 88: ...88 FR LISTE DES PI CES D TACH ES...
Page 90: ...90 FR REMARQUES...
Page 91: ...91 FR REMARQUES...
Page 92: ...ECR International Inc 2201 Dwyer Avenue Utica NY 13501 web site www ecrinternational com...