10
EADM
SPLIT-TYPE ROOM AIR CONDITIONER
Install the air freshening filter back into position.
Insert the upper portion of air filter back into the unit, taking
care that the left and right edges line up correctly and place
filter into position.
Remove the air filter.
Remove the air freshening filter.
Install a new air freshening filter.
Reinstall the air filter and securely close the front panel.
If you plan to idle the unit for a long time, perform the following:
Clean the indoor unit and filters.
Operate the fan for about half a day to dry the inside of the unit.
Stop the air conditioner and disconnect power.
Remove the batteries from the remote controller. The outdoor
unit require periodic maintenance and cleaning. Do not attempt
to do this yourself. Contact your dealer or service provider.
Check that the wiring is not broken off or disconnected.
Clean the indoor unit and filters.
Check that the air filter is installed.
Check if the air outlet or inlet is blocked after the air conditioner
has not been used for a long time.
5
6
1
2
3
4
1
2
3
4
CAUTIONS
CAUTIONS
Do not touch the metal parts of the unit when removing the filter.
Injuries can occur when handling sharp metal edges.
Do not use water to clean inside the air conditioner. Exposure to
water can destroy the insulation, leading to possible electric shock.
When cleaning the unit, first make sure that the power and circuit
breaker are turned off.
Do not wash air filter with hot water at more than 40º C / 104 ºF.
Shaken off moisture completely and dry it in the shade. Do not
expose it directly to the sun, it may shrink.
PRE-SEASON INSPECTION
REPLACE OF AIR FILTER AND FRESHING FILTER
PREPARATION FOR EXTENDED NON-OPERATION