SPLIT-TYPE ROOM AIR CONDITIONER
1
1
2
3
2
NOTE
NOTE
NOTE
OPERATING INSTRUCTIONS
This manual does not include Remote Controller Operation; see the
Remote Controller Instructions packed with the unit for details.
TEMPERATURE
Room Temperature
Outdoor Temperature
MODE
COOLING
OPERATION
HEATING
OPERATION
DRYING
OPERATION
17 ºC ~ 32 ºC
(62º F ~ 90º F)
0 ºC ~ 30ºC
(32º F ~ 86º F)
10º C ~ 32º C/ 50º F ~ 90º F
(<21000Btu/h models)
11º C ~ 43º C/ 52º F ~ 109º F
(<21000Btu/h models)
18º C ~ 52º C/ 64º F ~ 126º F
(For special tropycal models)
18 ºC ~ 43 ºC
(64º F ~ 109 ºF)
-7 ºC ~ 43 ºC
20º F ~ 109º F:
(For models with low
temperature cooling
system)
18 ºC ~ 52 ºC
64º F ~ 126º F:
(For special tropycal
models)
-7 ºC ~ 24 ºC
(20º F ~ 76ºF)
Optimum performance will be achieved within these operating
temperatures. If air conditioner is used outside of the above
conditions, certain safety protection features might come into
operation and cause the unit to function abnormally.
If the air conditioner runs for a long time in cooling mode and the
humidity is high(over 80%), condensed water may drip out of the
unit. Please sets the vertical air flow louver to its maximum angle
(vertically to the floor), and set HIGH fan mode.
Units are equipped with a
switch to run emergency
operation mode. It can be
accessed by opening the
front panel. This switch is
used for manual operation
in case the remote
controller fails to work or
maintenance necessary.
Hold the panel sides and lift the front panel up to an angle until
it remains bed with a clicking sound. For some models, please
use suspension bars to prop up the panel.
Once you push the manual button, the operation mode is
shifted in an order as AUTO COOL, OFF. The temperature will be
set at 24º C / 76º F and the fan on Auto.
After operation, close tile panel firmly to its original position.
CAUTIONS
This switch is used for testing purpose only. Please do not use it
unless necessary.
To restore the remote controller operation, use the remote
controller directly.
Best working conditions (the energy efficient can be affected if not
set under these conditions):
The best angle of louvers is the default angle of cooling mode.
The best way of setting the angle of louvers at heating mode is:
Run the unit for 5 minutes and then use the remote controller to
set the louvers at the default angle of cooling mode.
OPERATING TEMPERATURE
MANUAL OPERATION
IMPORTANT:
Do not put your fingers into the panel of blower and suction side.
The high-speed fan inside may cause danger.
Range
Range
Deflector rod
(two places)
Adjust the air flow direction
properly otherwise, it might cause
discomfort or cause uneven room
temperatures.
Adjust the horizontal louver using
the remote controller.
Adjust the vertical louver manually.
To set the vertical air flow (Up-
Down) direction:
Perform this function while the
unit is in operation. Use the remote
controller to adjust the air flow
direction. The horizontal louver
can be moved at a range of 6º each
time you press the button, or swing
up and down automatically. Please
refer to the “Remote Controller
Operation Manual” for details.
To set the horizontal air flow
direction (left – right):
Move the vertical louver manually
to adjust the air flow in the direction
you prefer.
AIRFLOW DIRECTION CONTROL
Manual switch
AUTO/COOL
Suspension bars
AUTO/COOL
(
1
)
(
2
)
Manual switch