clock not programmed

problem:

 

the time and date has not been set. 

the timers cannot be used.

solution:

 set the time and date and any timers in the 

respective menu.

maintenance request for cleaning

problem:

  there  are  100  operating  hours  left  from  the  time  of  the  message 

appearing before the stove will be blocked for cleaning.

solution:

 Arrange for a technician to clean the stove.

sudden power cutout

problem: 

the power has been down for more than a minute.

the stove signals the power cutout and shuts down.

alarm: gases not up to heat

problem:

 the discharge gases have become too cold; the embers have gone out.

cause:

 the pellets in the tank are finished. refill the tank.

alarm: start-up failed 

problem:

 the stove has not started up.

cause:

 

the brazier is dirty or not properly in place. No pellets. 

the element does not work. coNtAct the techNiciAN.

Vacuometer alarm

problem:

 trouble discharging the gases.

cause:

 the flue system is obstructed. coNtAct the techNiciAN.

alarm: overheating gas

problem:

 the temperature of the discharge gases has exceeded the permitted 

threshold.

cause:

 the gear motor is operating continuously, the gas probe is broken.

coNtAct the techNiciAN

alarm: stove overheating

problem:

 the body of the stove has exceeded the permitted threshold and is 

overheating.

solution:

 the fan is not cooling down the stove. coNtAct the techNiciAN.

alarm: gas evacuator motor

problem:

 the gas evacuator motor is not working or the board cannot detect 

its operation.

cause:

 the motor is not powered or the tachometer sensor is not responding. 

coNtAct the techNiciAN

annEx: aLarm and notiFication

All alarm and notification messages appear on the display, possible causes and solutions.

Summary of Contents for Lady

Page 1: ... used 4 Important instructions before ingnition 4 Recommendations for using the stove correctly 5 Installation 6 Combustion air inlet 7 Operation 8 Maintenance 10 Ordinary maintenance 10 Extraordinary maintenance 10 Mainenance of the smoke exhaust duct 11 Operating problems and solutions 12 Declaration of conformity 15 Guarantee 16 programming instructions PRETTY Pretty Cer NICE Nice Cer Lady Lady...

Page 2: ...ated as efficiently as possible and in complete safety The device must be installed correctly for safety reasons and to ensure proper operation The stove should never be used by people who do not know how to work it Keep children and animals away from the stove when it is in use This handbook has been written by the manufacturer and is an integral part of the product The information it contains is...

Page 3: ...ossible we recommend installing a T pipe for inspection at the stove exhaust gas outlet in order to recover the burnt microdust and also a steel pipe two metres high to be connected to the existing flue in order to discharge the flue gas This device will prevent smoke formation inside the rooms should there be a power failure for any reason during stove operation STANDARD EQUIPMENT User s and inst...

Page 4: ... pressed wood It is very important to choose a clean top quality pellet without impurities For the stove to work properly and safely it is necessary to use pellets that comply with the following standards DIN 51731 and ONORM M 7135 thermal value residual humidity diameter quality of wood used Ecowood cannot assume liability for poor operation of the stove if poor quality pellets are used Use only ...

Page 5: ... as to prevent the risk of burns or scalds or breakage or cracking of the glass itself Use special products for cleaning glass and the body work Take care not to knock against the stove as this could cause permanent damage If the glass is cracked or broken do not attempt to light the stove Do not open the door of the hearth when the stove is lit Always follow these instructions precisely when ligh...

Page 6: ...l insulate the material with suitable fireproof or fire resistant products Connect the flue pipe of your stove to an existing chimney or alternatively install a fume exhaust pipe outside the building The pipe must have a minimum pipe diameter of 80 mm and reach higher than the top of the roof If the stove is installed in a building with poten tially inflammable walls it will be necessary to place ...

Page 7: ...ET In order to guarantee good combustion the stove must receive enough air to ensure the fuel receives sufficient oxygen Connect the combustion air inlet to the outside so that it cannot be obstructed even partially in any way If the stove cannot be connected directly to the outside it is possible to install a permanent ventilation grating this will guarantee perfect combustion and hence lower pel...

Page 8: ... exclusively by the installer Is not possible to change the direction of the flue gas outlet on the stove with majolica covering NICE CER OPERATION After installing the stove as described above fill the tank on top of the stove with the pellets through the door on the stove The tank should always contain enough fuel to guarantee a regular supply to the stove and the door should be closed during op...

Page 9: ...fety therefore an automatic power limiting device has been installed as standard in the stove If the automatic power limiting device is disabled at the user s request this should be done by the installer technician following an evaluation of the conditions under which the stove is to be used it is necessary to connect the stove to the flue gas exhaust system using stainless steel pipes or pipes pa...

Page 10: ...aning Remove the panel fastened down with four screws and clean it carefully using a vacuum cleaner to suck out the dust deposited inside the exhaust flue and the ash box Take out the flue exhauster motor and clean the screw carefully Re assemble all the parts in the reverse order oiling the screws After carefully carrying out all necessary checks the automatic stove operation block ing device sho...

Page 11: ...r regulating both the exhaust pressure and pellet loading rate This should be carried out only by the installer technician at installation or when conditions make it necessary 2 A vertical metal exhaust pipe that is three four metres long will increase the combus tion rate This will cause the stove to go out at the minimum power level To prevent this just increase the selected power level or chang...

Page 12: ... it is not working make sure that it is pow ered if there is power and it turns slowly replace it with a new one if the flue exhauster motor stops the electronic board will immediately stop to feeding the pellet The screw motor is working properly If it is not working make sure that it is powered if there is power and it does not turn replace it with a new one if the motor reducer stops the stove ...

Page 13: ...er failure if there is a brief power failure 60 seconds when the stove is at the ignition stage or is operating normally the stove is programmed to re ignite itself If the power failure lasts for a longer indefinite period when the power returns the stove will go into an extinguishing cycle setting up for the next manual or programmed ignition In this case the display will show Black Out message T...

Page 14: ...d up Cause The brazier is dirty or not properly in place No pellets The element does not work CONTACT THE TECHNICIAN Vacuometer alarm Problem Trouble discharging the gases Cause The flue system is obstructed CONTACT THE TECHNICIAN Alarm overheating gas Problem The temperature of the discharge gases has exceeded the permitted threshold Cause The gear motor is operating continuously the gas probe is...

Page 15: ...place of issue _ _____________________________________________________________________________ Name and signature of authorised person ______________________________________________________________ Position in firm ___________________________________________________________________________________ Potenza termica nominale 7 0 kW Potenza termica ridotta 2 9 kW nominale 0 028 Modello PRETTY NICE CO ...

Page 16: ...rantee will this expire The guarantee does not cover the pellet loading auger gearbox the ignition resistance the glass and painted parts Other failures due to even partial lack of maintenance or incorrect installation The guarantee does not cover damage caused by transport It is therefore important to check the goods care fully on receipt and notify the retailer immediately if any damage is detec...

Reviews: