Burner

 

 

•  Direct Vent Freestanding Stove 

•  Natural Gas or Propane 

•  Vent Horizontally or Vertically 

• Standard Residential  

•  Mobile Home Approved 

Tested and Listed by 

 

ANSI Z21.88 CSA 2.33

 

WARNING

If the information in these instructions is not followed exactly, a fire or explosion may result 
causing property damage, personal injury or loss of life. 

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. 

WHAT TO DO IF YOU SMELL GAS 

•  Do not try to light any appliance. 
•  Do not touch any electrical switch; do not use any phone in your building. 
•  Immediately call gas supplier from a neighbor's phone. Follow the gas supplier's instructions. 
•  If you cannot reach your gas supplier, call the fire department. 

Installation and service must be performed by a qualified installer, service agency or the gas supplier. 

 

This appliance may be installed in an 
aftermarket permanently located, 
manufactured home (USA only) or mobile 
home, where not prohibited by local codes. 
 

This appliance is only for use with the 
type(s) of gas indicated on the rating 
plate.  A conversion kit is supplied with 
the appliance.

 

 

· Tree of Life 

 2 ·

 

Owner’s Manual 

Installer

After installation give this manual to the homeowner and 
explain the operation of this heater. 

©

 Copyright 2013, T.I.        $10.00       100-01313       4121128 

 

www.travisproducts.com 

4800 Harbour Pointe Blvd. SW 

Mukilteo, WA  98275

 

 

Содержание Avalon Tree of Life GS2

Страница 1: ...building Immediately call gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This appliance may be installed in an aftermarket permanently located manufactured home USA only or mobile home where not prohibited...

Страница 2: ...al support and guidanceto help you achieve the maximum benefit and enjoyment from your heater Important Information No other Tree of Life Stove has the same serial number as yours The serial number is on the listing plate chained to the gas control valve This serial number will be needed in case you require service of any type Model Avalon Tree of Life GS2 Serial Number Purchase Date Purchased Fro...

Страница 3: ...ts see illustration below 20 Class A Chimney Conversion Kit 21 Interior Masonry Chimney Conversions 22 Steps for Finalizing the Installation 23 Air Shutter Adjustment 24 Face and Glass Removal 25 Log Installation 27 Ember Placement 27 Rear Log Placement 27 Left Log Placement 28 Right Log Placement 28 Right Twig Placement 29 Left Twig Placement 29 Front Ember Chunk Placement 30 Rockwool Installatio...

Страница 4: ...afety hazard Direct questions about the type of fuel used to your dealer Check for a label on the flame adjust knob on the gas control valve this is the best place to check You may also check for a label on the gas control valve body Contact your local building officials to obtain a permit and information on any installation restrictions or inspection requirements in your area Notify your insuranc...

Страница 5: ...how to shut gas off to the appliance and at the gas main shutoff valve The gas main shutoff valve is usually next to the gas meter or propane tank and requires a wrench to shut off This unit is not for use with solid fuel Do not place anything inside the firebox except the included fiber logs If the fiber logs become damaged replace with Travis Industries log set Do not throw this manual away This...

Страница 6: ...me Straight or Corner Placement Bedroom Approved Heating Specifications Approximate Heating Capacity in square feet 500 1 500 with Blower 500 to 1 200 Without Maximum Input 31 000 Heating capacity will vary depending on the home s floor plan degree of insulation and the outside temperature Dimensions Weight Electrical Specifications for optional blower Electrical Rating 115 Volts 1 5 Amps 60 Hz 18...

Страница 7: ...nada CSA Z240 4 and Gas Equipped Recreational Vehicles and Mobile Housing This appliance may be installed in Manufactured Housing only after the home is site located This stove is designed to operate on natural gas or propane LP All exhaust gases must be vented outside the structure of the living area Combustion air is drawn from outside the living area structure Notify your insurance company befo...

Страница 8: ...u may wish to adjust the stove position slightly to ensure the vent does not intersect with a framing member Fumes and smoke from the paint curing and oil burning off the steel may occur the first time you start this heater This is normal We recommend you open windows to vent the room Stove Clearances Mobile Home Requirements When the stove is installed in a mobile home it must be bolted to the fl...

Страница 9: ...w or above the door along the sides of heater or along the back of the heater can become blocked This heater may be placed in a bedroom Please be aware of the large amount of heat this appliance produces when determining a location Floor Protection Requirements When the stove is installed directly on carpeting vinyl or other combustible material other than wood flooring or a high pressure laminate...

Страница 10: ...witch or thermostat Warning Make sure all wiring is secure and does not contact hot or moving components The wall switch or thermostat may bypass the fireplace on off switch or be installed in parallel or series configuration see below Parallel Connection Series Connection On Off Switch ON On Off Switch OFF On Off Switch ON On Off Switch OFF Thermostat External Switch ON Heater is ON Heater is ON ...

Страница 11: ...ng the heater The location of the gas inlet is shown below A manual shutoff valve is required for installation it must be located within 3 of the heater T Handle gas cocks are required in Massachusetts in compliance with code 248CMR This stove is shipped with a 24 long 3 8 diameter flex gas line attached to an elbow on the gas control valve see illustration below for location The flex accepts a 3 ...

Страница 12: ...d Consult your dealer or installer if you suspect an improperly adjusted air shutter This heater has been tested at altitudes ranging from sea level to 6 000 feet 1 800 M In this testing we have found that the heater with its standard orifice burns correctly with just an air shutter adjustment Approved Vent Use 6 5 8 168mm diameter Simpson Dura Vent Direct Vent Pro or GS Other vent may be approved...

Страница 13: ...uilt into the appliance to control the flow rate of exhaust gases This ensures proper flames for the wide variety of vent configurations Depending upon the vent configuration you may be required to adjust the restrictor position The charts for approved vent configurations describe which position the vent restrictor must be in Measuring Vent Lengths ...

Страница 14: ...21128 100 01313 Vertical Terminations with Zero Two or Four 45 Elbows 10 Minimum System Height with or without offsets 40 Maximum System Height 24 Maximum Offset The termination must fall within the shaded area shown in the chart Use the indicated restrictor position ...

Страница 15: ...ntal Termination with One 90 Elbow If using a Snorkel Termination 14 or 36 add the snorkel height to the vertical height snorkel terminations are used primarily for basement installations The terminationmust fall within the shaded areashown inthe chart Usethe indicated restrictor position ...

Страница 16: ...wo Elbows one 90 vertical and one 90 or 45 horizontal elbow If using a Snorkel Termination 14 or 36 add the snorkel height to the vertical height snorkel terminations are used primarily for basement installations The terminationmust fall within the shaded areashown inthe chart Usethe indicatedrestrictor position ...

Страница 17: ...rmination with Three 90 Elbows all vertical If using a Snorkel Termination 14 or 36 add the snorkel height to the vertical height snorkel terminations are used primarily for basement installations The terminationmust fall within the shaded areashown inthe chart Usethe indicatedrestrictor position ...

Страница 18: ...tion for qualified installers only Travis Industries 4121128 100 01313 Vertical Terminations with Two 90 Elbows The terminationmust fall within the shaded areashown inthe chart Usethe indicated restrictor position ...

Страница 19: ... only 19 Travis Industries 4121128 100 01313 Vertical Terminations with Three 90 Elbows Two 90 Vertical and One 45 or 90 Horizontal Elbow The terminationmust fall within the shaded areashown inthe chart Usethe indicatedrestrictor position ...

Страница 20: ...he floor NOTE Clearance in accordance with local installation codes and the requirements of the gas supplier G Minimum 48 1219mm clearance from any adjacent building H Minimum 84 2134mm clearance above any grade when adjacent to public walkways or driveways NOTE may not be used over a walkway or driveway shared by an adjacent building I Minimum 9 229mm clearance to any non mechanical air supply in...

Страница 21: ...on based upon the vertical rise height see the chart on page 14 The conversion kit does not work on interior masonry chimneys Chimney Conversion Kit A 931 Metalbestos 6 I D Security Chimneys 6 I D Jackes Evans 6 I D Hart Cooley 6 I D Pro Jet 6 I D Chimney Conversion Kit B 932 Simpson Dura Vent 6 I D Air Jet 6 I D Metal Fab 6 and 7 I D Amer Metals 6 7 I D Metalbestos 7 and 8 I D Jackes Evans 7 and ...

Страница 22: ...ts and use the equipment listed in the illustration below to install this appliance into an interior masonry chimney Maximum vertical rise is 40 Minimum vertical rise is 10 See the charton page 18 for determiningthe correctrestrictor position NOTE these restrictorpositionsarebasedupon lab tests The ideal restrictor positionmay vary slightly ...

Страница 23: ...d once it enters the firebox ensuring gas does not build up 3 Make sure the accent light bulb is in place NOTE Take care to not touch the bulb with your fingers use a cloth or paper towel 4 Install the four AA batteries included in the owner s pack into battery holder see the illustration below The AA batteries act as a power backup in case the household AC power goes out Install the 9v battery in...

Страница 24: ... logs and glass are in place The flames should be yellow with no sooting Adjust the air shutter if necessary to achieve the correct looking flame 10 Turn the flame adjust knob to its highest position the flames should not contact the top of the firebox Check the flame on low position The flames should burn off of each burner hole If the heater does not work correctly contact your Travis dealer for...

Страница 25: ...lizing the Installation for qualified installers only 25 Travis Industries 4121128 100 01313 Face and Glass Removal Make sure the gas control valve is OFF and the heater is cool prior to conducting service ...

Страница 26: ...ravis Industries 4121128 100 01313 Glass Frame Removal and Installation continued The latch can come loose from glass frame anchor This occurs when it is turned 1 4 turn when it is disengaged Follow the directions below to re install the latch if it becomes loose ...

Страница 27: ...n property damage or personal injury If using propane LP convert the appliance before installing the logs see page 40 The burner must be correctly positioned before installing the logs Make sure the burner is fully seated and the pilot is properly aligned See page 40 for details on burner removal Ember Placement Place a layer of embers along the any visible edges of the burner Also place an ember ...

Страница 28: ... left log has two holes on the bottom Place the log so the pin on the burner and the metal bracket insert into the holes on the log see photos below Right Log Placement The right log has two holes on the bottom Place the log so the pin on the burner and the metal bracket insert into the holes on the log see photos below ...

Страница 29: ...over the right pin on the back log see photos below The lower side of the twig rests on the right log Place the twig as shown below Left Twig Placement The left twig has two holes in the bottom of it for this model place the log so the left pin on the rear log inserts into the lower hole see photo below The bottom of the log rests on the left log Place the log as shown below ...

Страница 30: ...stallation The included rock wool is placed on top of the burner to enhance the glow from the burner The rock wool works best when it is applied in a very thin porous layer The best method for applying the rock wool is to brush it on to the burner Compress a clump of rockwool between your thumb and forefinger Use a stiff brush to apply a thin layer of rockwool fibers onto the burner Do not use the...

Страница 31: ...lanation below Optional Blower Control This knob controls the speed of the optional internal convection blower that pushes heated air into the room Accent Light This knob controls the accent lights located behind the logs Flame Adjust Knob This knob controls the flame height from low LO to high HI Continuous Pilot GreenSmart Pilot This switch controls how the pilot flame works See the section Cont...

Страница 32: ...e Stove On and Off Use the main burner switch to turn the main burner on and off NOTE FOR REMOTES THERMOSTATS OR WALL SWITCHES The on off switch on the stove may be required to be left in the ON or OFF position for the stove to operate Consult your installer or dealer for details Do not place any combustible items on top of or directly in front of the stove even temporarily An optional thermostat ...

Страница 33: ...eowner may prefer to switch the stove to continuous pilot The most typical reasons for switching to continuous pilot are Very Cold Conditions in very cold conditions you may notice that the burner does not light quickly and the flames lift off the burner If this is situation we recommend you switch to continuous pilot This will create a slight draft in the vent allowing for the burner to light qui...

Страница 34: ...mal Operating Odors This appliance has several areas that reach high temperatures Dust or other particles on these areas may burn and create a burnt paper smell This is normal during startup You may notice the smell is more acute if the appliance was left idle for a long period ...

Страница 35: ...ly dull in appearance especially over the top where it becomes hot This is normal The only cleaning we recommend is a light dusting when the appliance is cool DO NOT USE ANY LIQUID CLEANER OR ABRASIVES ON THIS FINISH Glass Clean the glass with soap and water do not use abrasive cleaners Glass removal instructions are on page 25 Battery Replacement Power Backup Batteries Four AA batteries are used ...

Страница 36: ...oot along the bottom of the logs is normal If excessive sooting is found the stove will require adjustment Contact your dealer 4 Inspect the burner and remove any debris Make sure the burner is not warped cracked or damaged Check the firebox and area around the pilot to make sure there is no warping or damage If any problem is found discontinue use and contact your dealer for service 5 Replace the...

Страница 37: ...ture The blower fuse may be blown Check the breaker switch Let the stove burn for at least 15 minutes Replace the blower fuse See fuse location below Flames Are Too Blue The stove has just been started Improper air shutter adjustment This is normal see Starting the Stove for the First Time Adjust Air Shutter contact your dealer Flames Are Too Short Under 6 The flame height may be turned too low Tu...

Страница 38: ...system to vent this appliance to the exterior See owner s manual for approved brands of venting If the vent air intake system is disconnected for servicing or any other reason it must be resealed and or reinstalled WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For a...

Страница 39: ...ent of the manufacturer s settingsof components lackof proper and regular maintenance damage incurred whilethe appliance isin transit alteration or act of God 8 This7 Year warranty excludesdamagecaused by normal wear and tear such aspaint discolorationor chipping worn or torn gasketing corrodedor cracked logs embers etc Also e xcludedis damage to the unit caused by abuse improper installation modi...

Страница 40: ...using property damage personal injury or loss of life The qualified service agency is responsible for the proper installation of this kit The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer s instructions supplied with the kit Install the conversion kit prior to installing the gas line to ensure proper gas use 1 Rem...

Страница 41: ...4121128 100 01313 4 Follow the directions below to replace the orifices ORIFICE SIZE Natural Gas LP Propane Front Burner Orifice 50 DMS 58 DMS Rear Burner Orifice 47 DMS 56 DMS Front Burner Orifice a Rear Burner Orifice c 15 16 24mm b Orifice ID Thread Sealant 1 2 Wrench ...

Страница 42: ...gulator in place see b below Remove the stock regulator and gasket see c below Place the LP regulator in place making sure the pre fitted gasket see c below is in place NOTE There is a label on the base of the regulator knob indicating regulator type NG or LP Secure the regulator with the screws included with the regulator tighten to 25 lb in of torque Place the included label on the valve body wh...

Страница 43: ...he remote Remote Control Pilot Warnings Installing batteries in the battery holder or connecting the appliance to power may automatically initiate the CPI pilot mode resulting in a lit pilot flame Do not place combustibles in the firebox KEEP BATTERIES AND COVER INSTALLED AT ALL TIMES The remote control system requires the batteries and battery cover to remain in place at all times Once the batter...

Страница 44: ...lower Hookup Pilot Sensor Appliance Ground Accessory Power Green Orange Yellow Green White Blue IPI CPI Switch 120 VAC Power In Black Red Yellow Black White Green Base Integrated Fireplace Control IFC 3 15A FUSE Red Red Black White Green Red Blue Red Blue Black ON OFF Comfort Control Switch AA Battery Tray Main Burner Switch Comfort Control Valve Accent Light Rheostat Accent Light s 2 5 Amp Fuse S...

Страница 45: ...y Box Manual On Off Accent Light s 2 5 Amp Fuse Optional Blower s 2 5 Amp Fuse Appliance Ground Accessory Power Appliance Ground Green Orange Yellow Green White Blue IPI CPI JUMPER WIRE Blue Pink 120 VAC Power In TOP 4 AA Batteries Black Red Yellow Orange Yellow Flame Detect Black Red Purple Grey Black White Green Integrated Fireplace Control IFC 3 15A FUSE White Black White Black Black Black Whit...

Страница 46: ...trol Battery Plate from the control panel keep the screws 2 Remove the control panel and place face downin front of the heater keep the screws 3 Disconnectthe comfort control and battery backup wires 4 Remove and place aside the Comfort Control Battery Plate with harness the batteries and assembly may be kept for spare parts ...

Страница 47: ...s Industries 4121128 100 01313 5 Remove the rear panel from the heater and set aside It is held in place with seven screws 6 Disconnectinput power 7 Pull the base IFC to the rear of the stove to accessthe wiring it is held in place with Velcro Screw Locations ...

Страница 48: ...sconnectthe following Power 3 wires Main harness On Off wires Pilot connections slide silicone tubing up 9 Remove and place aside the base IFC it may be kept for spare parts 10 Remove the on off switch by prying it out Disconnectthe wires 11 Push the wires back into the holder to conceal them ...

Страница 49: ... gasket see c below 13 The stepper motor adjustable regulator has an installation sheet included with it make sure to follow all of the directions Placethe stepper motor on the gas control valve see below MAKE SURE IT IS CORRECTLY ORIENTED Secureusing the screws included with the motor tighten to 25 Lb inches Leak test this area after installation to verify proper installation Route the stepper mo...

Страница 50: ...er the IFC is placed in location see e below Wiring the Blower to the GSR2 IFC Bypassing the Rheostat and Snap Disc Disconnect the blower power input see a below Connect the blower wiring harness to the fuse output see b below Disconnect and discard the electrical line intended to connect the snap disk to the rheostat carefully remove the wire tie from the wiring harness see c Attach the jumper wi...

Страница 51: ...cent Light to the GSR2 IFC Bypassing the Rheostat a Disconnect the accent light power input see a below b Disconnect the quick connects and molex connection leading to the switch box see b below NOTE the switch box and wiring may be removed and discarded or saved for spare parts c Attach the power lead included with the remote to the molex from the fuse labeled L or LIGHT see c below Attach the qu...

Страница 52: ...s only Travis Industries 4121128 100 01313 16 Attach the following Power 3 wires make sure orientation is correct Pilot connections Make sure siliconetubing is pushed down Comfort Control connection Main Harness Stepper Motor N White L Black Green ...

Страница 53: ...nnectthe IPI CP switch from IPI CP wires Attach one of the jumper wires to the two wires Discardthe IPI CP switch 18 Remove the IPI CPI switchand place aside may be kept for spare parts 19 Connect the accent light wires to the GSR2 IFC NOTE If using a blower connect the power input to the GSR2 IFC ...

Страница 54: ...ector to the main harness molex connector 21 Route the battery box harness through the control panel and attach to the battery box 22 Place the IFC in location inside the heater and attach using the supplied velcro tape 23 Use the two included cable ties to make sure all wiring is secure and does not contact any hot or moving parts ...

Страница 55: ...Optional Equipment for qualified installers only 55 Travis Industries 4121128 100 01313 24 Re attach the control panel 25 Attach the battery box to the control panel using the screws removed in step 2 ...

Страница 56: ...Industries 4121128 100 01313 26 Re connect the input power 27 Replace the rear panel and restore the stove to the correctconfiguration turnon power and gas See the instructions included with the remote for synchronizing the remote and the operating instructions ...

Страница 57: ...Optional Equipment for qualified installers only 57 Travis Industries 4121128 100 01313 ...

Страница 58: ...Three 90 Elbows 17 Horizontal Termination with Two Elbows 16 Important Information 2 Installation Hints 8 Installation Options 6 Installation Overview 7 Installation Warnings 7 Interior Masonry Chimney Conversions 22 Listing Details 2 Location of Controls 31 Log Installation 27 LP Conversion Instructions 40 Maintaining Your Stove s Appearance 35 Mobile Home Requirements 8 Normal Operating Odors 34...

Отзывы: